CoChat

Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla

Open access
Polders, Daniel L., Leemans, Alexander, Hendrikse, Jeroen, Donahue, Manus J., Luijten, Peter R., Hoogduin, Johannes M. · 2011 · Journal of Magnetic Resonance Imaging
Cited by 129

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: To compare diffusion tensor imaging (DTI) measurements at ultra high field strength (7 Tesla [T]) in human volunteers with DTI measurements performed at 1.5 and 3 Tesla. Materials and Methods: The signal to noise ratio (SNR) and the uncertainty in fitted DTI parameters fractional anisotropy and primary eigenvector are assessed with tractography based regions of interest, measured in nine volunteers at 1.5T, 3T, and 7T with clinically available hardware configurations. Results: An increase in SNR is observed on the 7T system compared with the 1.5 or 3T system. The measured increase in SNR at 7T is larger than expected from field strength alone, indicating the large influence of improved receive coil hardware. Additionally, while the average fractional anisotropy remains relatively constant across field strengths, a decrease in uncertainty in the fitted values for fractional anisotropy and the principal eigenvector of the DTI tensor was found. Increased spatial heterogeneity of signal intensities is observed at 7T. Conclusion: Given the current hardware constraints, DTI at ultra‐high field strengths is possible with improved performance in selected regions of interest. J. Magn. Reson. Imaging 2011;33:1456–1463. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.22554

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 129

Metadata

Authors
Polders, D. L., Leemans, A., Hendrikse, J., Donahue, M. J., Luijten, P. R., & Hoogduin, J. M.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2011-05-17
Volume
33
Issue
6
Pages
1456-1463
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2023442941
Cited by
129
References
2
FWCI
6.20
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla. https://app.cochat.ai/papers/10.1002/jmri.22554
The paper
Polders, D. L., Leemans, A., Hendrikse, J., Donahue, M. J., Luijten, P. R., & Hoogduin, J. M. (2011). Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22554

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.