CoChat

High‐resolution MRI and diffusion‐weighted imaging of the human habenula at 7 tesla

Open access
Strotmann, Barbara, Heidemann, Robin M., Anwander, Alfred, Weiss, Marcel, Trampel, Robert, Villringer, Arno, Turner, Robert · 2014 · Journal of Magnetic Resonance Imaging
Cited by 71

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Purpose: To investigate the feasibility of discriminating the habenula in human brain using high‐resolution structural MRI and diffusion‐weighted imaging at 7 Tesla (T). Materials and Methods: MRI experiments included a MP2RAGE and GRE sequence to acquire quantitative parameter maps of T1, T2*, and a calculated proton density map and the combined approach of zoomed and parallel imaging (ZOOPPA) to obtain dw images. Probabilistic tractography algorithms were used to identify multiple fiber orientations in submillimetre voxels, and constrained spherical deconvolution to resolve orientations in regions where fibers cross. Results: Maps of T1, T2*, and proton density showed high contrast of the human habenula. The lateral habenula and its commissure can be distinguished from medial habenula and adjacent tissue. DWI data with 0.7 mm isotropic resolution revealed that fiber populations differ in medial and lateral habenula and two major fiber bundles that connect habenular nuclei with forebrain structures and brainstem. Conclusion: High resolution 7T MR imaging of the human habenula provides sufficient signal‐to‐noise and contrast to enable identification of the lateral and medial nuclei. In vivo high resolution DWI at 7T is able to distinguish between lateral and medial habenula, and to detect major fiber tracts that connect the habenula with other brain areas. J. Magn. Reson. Imaging 2014;39:1018–1026. © 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.24252

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 71

Metadata

Authors
Strotmann, B., Heidemann, R. M., Anwander, A., Weiss, M., Trampel, R., Villringer, A., & Turner, R.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2013-11-20
Volume
39
Issue
4
Pages
1018-1026
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1543649206
Cited by
71
References
12
FWCI
4.28
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐resolution MRI and diffusion‐weighted imaging of the human habenula at 7 tesla. https://app.cochat.ai/papers/10.1002/jmri.24252
The paper
Strotmann, B., Heidemann, R. M., Anwander, A., Weiss, M., Trampel, R., Villringer, A., & Turner, R. (2014). High‐resolution MRI and diffusion‐weighted imaging of the human habenula at 7 tesla. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.24252

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.