Association of overall survival in patients with newly diagnosed glioblastoma with contrast-enhanced perfusion MRI: Comparison of intraindividually matched T1- and T2*-based bolus techniques: Comparison of T1- and T2*-Based Bolus Techniques
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To compare intraindividual dynamic susceptibility contrast (DSC) and dynamic contrast enhanced (DCE) MR perfusion parameters and determine the association of DCE parameters with overall survival (OS) with the established predictive DSC parameter cerebral blood volume (CBV) in patients with newly diagnosed glioblastoma. METHODS: Perfusion data were analyzed retrospectively, and included scans performed preoperatively at 3.0 Tesla in 37 patients (25 males, 12 females, 39-83 years, median 65) later diagnosed with glioblastoma. All patients received standard treatment consisting of surgery and radiochemotherapy. Images were spatially coregistered and maximum region of interest-based DCE and DSC parameter measurements compared and thresholds identified using multivariate linear regression, Pearson's correlation coefficients and using receiver operating characteristic analysis. Survival analysis was performed using Kaplan-Meier curves. RESULTS: While both, elevated volume transfer constant (K(trans) ) (>0.29 min(-1) ; P = 0.041) and CBV (>23.7 mL/100 mL; P < 0.001) were significantly associated with OS, elevated CBV was associated with worse OS compared with elevated K(trans) . K(trans) was significantly correlated with the leakage correction factor K2 but not with CBV. CONCLUSION: The combined use of DSC and DCE MR perfusion may provide additional information of prognostic value for glioblastoma patient survival prediction. As K(trans) was not tightly coupled to CBV, both parameters may reflect different stages in the pathogenetic sequence of glioblastoma growth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266 · cited 1×
“The intrinsic tissue T10 was set to 1000 ms according to literature values (37).”
BackgroundChaichana, K. L., Pendleton, C., Chambless, L., Camara-Quintana, J., Nathan, J. K., Hassam-Malani, L., Li, G., Harsh, G. R., Thompson, R. C., Lim, M., et al. (2013) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2013.02.007 · Cited by 43
Cited by
Bakas, S., Akbari, H., Sotiras, A., Bilello, M., Rozycki, M., Kirby, J. S., Freymann, J. B., Farahani, K., & Davatzikos, C. (2017) · Scientific Data · doi:10.1038/sdata.2017.117 · Cited by 3,049
Kickingereder, P., Burth, S., Wick, A., Götz, M., Eidel, O., Schlemmer, H.-P., Maier-Hein, K. H., Wick, W., Bendszus, M., Radbruch, A., et al. (2016) · Radiology · doi:10.1148/radiol.2016160845 · Cited by 446
Self-citationMacyszyn, L., Akbari, H., Pisapia, J. M., Da, X., Attiah, M., Pigrish, V., Bi, Y., Pal, S., Davuluri, R. V., Roccograndi, L., et al. (2016) · Neuro-Oncology · doi:10.1093/neuonc/nov127 · Cited by 301
Boxerman, J. L., Quarles, C. C., Hu, L. S., Erickson, B. J., Gerstner, E. R., Smits, M., Kaufmann, T. J., Barboriak, D. P., Huang, R. H., Wick, W., et al. (2020) · Neuro-Oncology · doi:10.1093/neuonc/noaa141 · Cited by 206
Self-citationTherapeutic options in recurrent glioblastoma—An update
Seystahl, K., Wick, W., & Weller, M. (2016) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2016.01.018 · Cited by 199
“perfusion imaging, dynamic susceptibility contrast, apparent diffusion coefficient and MR spectroscopy [12-18].”
Self-citationBakas, S., Sako, C., Akbari, H., Bilello, M., Sotiras, A., Shukla, G., Rudie, J. D., Santamaría, N. F., Kazerooni, A. F., Pati, S., et al. (2022) · Scientific Data · doi:10.1038/s41597-022-01560-7 · Cited by 193
Pati, S., Baid, U., Edwards, B., Sheller, M. J., Foley, P., Anthony Reina, G., Thakur, S., Sako, C., Bilello, M., Davatzikos, C., et al. (2022) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac9449 · Cited by 51
Richter, V., Nägele, T., Erb, G., Klose, U., Ernemann, U., & Hauser, T.-K. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111293 · Cited by 8
Metadata
- Authors
- Bonekamp, D., Deike, K., Wiestler, B., Wick, W., Bendszus, M., Radbruch, A., & Heiland, S.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2014-09-22
- Volume
- 42
- Issue
- 1
- Pages
- 87-96
- ISSN
- 1053-1807 (ISSN-L)
- OpenAlex
- W1836087675
- Cited by
- 67
- References
- 2
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.