Consensus recommendations for a dynamic susceptibility contrast MRI protocol for use in high-grade gliomas

Open access
Boxerman, Jerrold L, Quarles, Chad C, Hu, Leland S, Erickson, Bradley J, Gerstner, Elizabeth R, Smits, Marion, Kaufmann, Timothy J, Barboriak, Daniel P, Huang, Raymond H, Wick, Wolfgang, Weller, Michael, Galanis, Evanthia, Kalpathy-Cramer, Jayashree, Shankar, Lalitha, Jacobs, Paula, Chung, Caroline, van den Bent, Martin J, Chang, Susan, Al Yung, W K, Cloughesy, Timothy F, Wen, Patrick Y, Gilbert, Mark R, Rosen, Bruce R, Ellingson, Benjamin M, Schmainda, Kathleen M, Jumpstarting Brain Tumor Drug Development Coalition Imaging Standardization Steering Committee, Arons, David F, Kingston, Ann, Sandak, David, Wallace, Max, Musella, Al, Haynes, Chas · 2020 · Neuro-Oncology
Cited by 206

The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.

Abstract

Despite the widespread clinical use of dynamic susceptibility contrast (DSC) MRI, DSC-MRI methodology has not been standardized, hindering its utilization for response assessment in multicenter trials. Recently, the DSC-MRI Standardization Subcommittee of the Jumpstarting Brain Tumor Drug Development Coalition issued an updated consensus DSC-MRI protocol compatible with the standardized brain tumor imaging protocol (BTIP) for high-grade gliomas that is increasingly used in the clinical setting and is the default MRI protocol for the National Clinical Trials Network. After reviewing the basis for controversy over DSC-MRI protocols, this paper provides evidence-based best practices for clinical DSC-MRI as determined by the Committee, including pulse sequence (gradient echo vs spin echo), BTIP-compliant contrast agent dosing (preload and bolus), flip angle (FA), echo time (TE), and post-processing leakage correction. In summary, full-dose preload, full-dose bolus dosing using intermediate (60°) FA and field strength-dependent TE (40–50 ms at 1.5 T, 20–35 ms at 3 T) provides overall best accuracy and precision for cerebral blood volume estimates. When single-dose contrast agent usage is desired, no-preload, full-dose bolus dosing using low FA (30°) and field strength-dependent TE provides excellent performance, with reduced contrast agent usage and elimination of potential systematic errors introduced by variations in preload dose and incubation time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/neuonc/noaa141

Cites

68 of 68 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 68 references

Cited by

See all 206

Metadata

Authors
Boxerman, J. L., Quarles, C. C., Hu, L. S., Erickson, B. J., Gerstner, E. R., Smits, M., Kaufmann, T. J., Barboriak, D. P., Huang, R. H., Wick, W., Weller, M., Galanis, E., Kalpathy-Cramer, J., Shankar, L., Jacobs, P., Chung, C., van den Bent, M. J., Chang, S., Al Yung, W. K., Cloughesy, T. F., Wen, P. Y., Gilbert, M. R., Rosen, B. R., Ellingson, B. M., Schmainda, K. M., Jumpstarting Brain Tumor Drug Development Coalition Imaging Standardization Steering Committee, Arons, D. F., Kingston, A., Sandak, D., Wallace, M., Musella, A., & Haynes, C.
Venue
Neuro-Oncology
Published
2020-06-09
Volume
22
Issue
9
Pages
1262-1275
ISSN
  • 1522-8517 (ISSN-L)
  • 1523-5866
OpenAlex
W3033939517
Cited by
206
References
68
FWCI
12.10
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Consensus recommendations for a dynamic susceptibility contrast MRI protocol for use in high-grade gliomas. https://app.cochat.ai/papers/10.1093/neuonc/noaa141
The paper
Boxerman, J. L., Quarles, C. C., Hu, L. S., Erickson, B. J., Gerstner, E. R., Smits, M., Kaufmann, T. J., Barboriak, D. P., Huang, R. H., Wick, W., Weller, M., Galanis, E., Kalpathy-Cramer, J., Shankar, L., Jacobs, P., Chung, C., van den Bent, M. J., Chang, S., Al Yung, W. K., . . . Haynes, C. (2020). Consensus recommendations for a dynamic susceptibility contrast MRI protocol for use in high-grade gliomas. Neuro-Oncology. https://doi.org/10.1093/neuonc/noaa141

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.