CoChat

Reproducibility of MR‐based liver fat quantification across field strength: Same‐day comparison between 1.5T and 3T in obese subjects

Open access
Artz, Nathan S., Haufe, William M., Hooker, Catherine A., Hamilton, Gavin, Wolfson, Tanya, Campos, Guilherme M., Gamst, Anthony C., Schwimmer, Jeffrey B., Sirlin, Claude B., Reeder, Scott B. · 2015 · Journal of Magnetic Resonance Imaging
Cited by 82

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Purpose: To examine the reproducibility of quantitative magnetic resonance (MR) methods to estimate hepatic proton density fat‐fraction (PDFF) at different magnetic field strengths. Materials and Methods: This Health Insurance Portability and Accountability Act (HIPAA)‐compliant study was approved by the Institutional Review Board. Following informed consent, 25 severely obese subjects (mean body mass index [BMI]: 45 ± 4, range: 38–53 kg/m 2) were scanned at 1.5T and 3T on the same day. Two confounder‐corrected multiecho chemical shift‐encoded gradient‐echo‐based imaging methods were acquired to estimate PDFF over the entire liver: 3D complex‐based (MRI‐C) and 2D magnitude‐based (MRI‐M) MRI. Single‐voxel MR spectroscopy (MRS) was performed in the right liver lobe. Using linear regression, pairwise comparisons of estimated PDFF were made between methods (MRI‐C, MRI‐M, MRS) at each field strength and for each method across field strengths. Results: 1.5T vs. 3T regression analyses for MRI‐C, MRI‐M, and MRS PDFF measurements yielded R 2 values of 0.99, 0.97, and 0.90, respectively. The best‐fit line was near unity (slope(m) = 1, intercept(b) = 0), indicating excellent agreement for each case: MRI‐C (m = 0.92 [0.87, 0.99], b = 1.4 [0.7, 1.8]); MRI‐M (m = 1.0 [0.90, 1.08], b = –1.4 [–2.4, −0.5]); MRS (m = 0.98 [0.82, 1.15], b = 1.2 [–0.2, 3.0]). Comparing MRI‐C and MRI‐M yielded an R 2 = 0.98 (m = 1.1 [1.02, 1.16], b = –1.8 [–2.8, −1.1]) at 1.5T, and R 2 = 0.99 (m = 0.98 [0.93, 1.03], b = 1.2 [0.7, 1.7]) at 3T. Conclusion: This study demonstrates that PDFF estimation is reproducible across field strengths and across two confounder‐corrected MR‐based methods. J. Magn. Reson. Imaging 2015;42:811–817.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.24842

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 82

Metadata

Authors
Artz, N. S., Haufe, W. M., Hooker, C. A., Hamilton, G., Wolfson, T., Campos, G. M., Gamst, A. C., Schwimmer, J. B., Sirlin, C. B., & Reeder, S. B.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2015-01-23
Volume
42
Issue
3
Pages
811-817
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1482049253
Cited by
82
References
8
FWCI
8.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of MR‐based liver fat quantification across field strength: Same‐day comparison between 1.5T and 3T in obese subjects. https://app.cochat.ai/papers/10.1002/jmri.24842
The paper
Artz, N. S., Haufe, W. M., Hooker, C. A., Hamilton, G., Wolfson, T., Campos, G. M., Gamst, A. C., Schwimmer, J. B., Sirlin, C. B., & Reeder, S. B. (2015). Reproducibility of MR‐based liver fat quantification across field strength: Same‐day comparison between 1.5T and 3T in obese subjects. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.24842

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.