Reproducibility measurement of glutathione, GABA, and glutamate: Towards in vivo neurochemical profiling of multiple sclerosis with MR spectroscopy at 7T: Neurochemical Profiling of MS With MRS
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
PURPOSE: H magnetic resonance spectroscopy (MRS). MATERIALS AND METHODS: Five healthy subjects were studied twice in separate 1-hour sessions at 7T. One MS patient was also scanned once. GSH and GABA were measured with J-difference editing using a semilocalized by adiabatic selective refocusing sequence (semi-LASER, TE = 72 msec). A stimulated echo acquisition mode sequence (STEAM, TE = 10 msec) was used to detect glutamate along with the overall biochemical profile. Spectra were quantified with LCModel. Quantification accuracy was assessed through Cramer-Rao lower bounds (CRLB). Reproducibility of the metabolite quantification was tested using coefficients of variation (CoV). RESULTS: CRLB were ≤7% for GSH, GABA, and glutamate and average CoV of 7.8 ± 3.2%, 9.5 ± 7.0%, and 3.2 ± 1.7% were achieved, respectively. The average test/retest concentration differences at this measurement reproducibility and quantification accuracy were smaller for GABA and glutamate than intersubject variations in metabolite content with CoV ratios of 0.6 and 0.8, respectively. As proof of principle, GSH, GABA, and glutamate were also detected in an MS patient. CONCLUSION: GSH, GABA, glutamate, and other metabolites relevant in MS can be quantified at 7T with high accuracy and reproducibility in a single 1-hour session. This methodology might serve as a clinical research tool to investigate biochemical markers associated with MS. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:187-198.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
Defining the clinical course of multiple sclerosis: The 2013 revisions
Lublin, F. D., Reingold, S. C., Cohen, J. A., Cutter, G. R., Sørensen, P. S., Thompson, A. J., Wolinsky, J. S., Balcer, L. J., Banwell, B., Barkhof, F., et al. (2014) · Neurology · doi:10.1212/wnl.0000000000000560 · Cited by 3,177
Inhibitory role for GABA in autoimmune inflammation
Bhat, R., Axtell, R., Mitra, A., Miranda, M., Lock, C., Tsien, R. W., & Steinman, L. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0915139107 · Cited by 509 · cited 1×
“The immediate role of the inhibitory neurotransmitter GABA in MS is still unknown, but its anti-inflammatory potential has been suggested based on the concurrent observations of increased GABAergic activity and reduced inflammation in animals with experimental autoimmune encephalomyelitis (EAE), a murine model of brai…”
BackgroundIn vivo 1 H NMR spectroscopy of the human brain at 7 T
Tkáč, I., Andersen, P., Adriany, G., Merkle, H., Uǧurbil, K., & Gruetter, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1213 · Cited by 394 · cited 1×
“Increasing magnetic field strength improves the overall MRS detection sensitivity and enhances spectral dispersion, which allows the separation of glutamate and glutamine at 7T.(24) The aim of this study was to determine the accuracy and reproducibility of a comprehensive single-session measurement of GSH, GABA, gluta…”
Background13 C MRS studies of neuroenergetics and neurotransmitter cycling in humans
Rothman, D. L., De Feyter, H. M., de Graaf, R. A., Mason, G. F., & Behar, K. L. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1772 · Cited by 290 · cited 1×
“Glutamate is closely linked to glutamine by the glutamate-glutamine cycle,(15) a process that depends on the neurotransmission rate.(16) As such, the link between GSH and other metabolites is neither negligible nor is it purely chemical in nature, but is dynamically influenced by brain function and neurotransmitter ho…”
BackgroundSelf-citationBednařík, P., Tkáč, I., Giove, F., DiNuzzo, M., Deelchand, D. K., Emir, U. E., Eberly, L. E., & Mangia, S. (2015) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.233 · Cited by 191
Lin, Y., Stephenson, M. C., Xin, L., Napolitano, A., & Morris, P. G. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.33 · Cited by 163 · cited 2×
“3 mM).(38,46,57,58) The reproducibility of glutamate quantification at 7T by means of CoV values has been explored previously in different areas of the human brain.”
BackgroundJuchem, C., Umesh Rudrapatna, S., Nixon, T. W., & de Graaf, R. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.011 · Cited by 74
Self-citation
Cited by
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Detcheverry, F., Senthil, S., Narayanan, S., & Badhwar, A. (2023) · NeuroImage: Clinical · doi:10.1016/j.nicl.2023.103503 · Cited by 64
In Vivo Brain GSH: MRS Methods and Clinical Applications
Bottino, F., Lucignani, M., Napolitano, A., Dellepiane, F., Visconti, E., Rossi Espagnet, M. C., & Pasquini, L. (2021) · Antioxidants · doi:10.3390/antiox10091407 · Cited by 50
“In fact, the STEAM sequence provides efficient suppression of unwanted coherence pathways, producing high quality spectra with very short TEs (5–10 ms) [9].”
BackgroundMethodInfluentialLancaster, M. S., Kim, B., Doud, E. H., Tate, M. D., Sharify, A. D., Gao, H., Chen, D., Simpson, E., Gillespie, P., Chu, X., et al. (2023) · Cell Reports · doi:10.1016/j.celrep.2023.113241 · Cited by 32
Metadata
- Authors
- Prinsen, H., de Graaf, R. A., Mason, G. F., Pelletier, D., & Juchem, C.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2016-06-28
- Volume
- 45
- Issue
- 1
- Pages
- 187-198
- ISSN
- 1053-1807 (ISSN-L)
- OpenAlex
- W2473984363
- Cited by
- 84
- References
- 8
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility measurement of glutathione, GABA, and glutamate: Towards in vivo neurochemical profiling of multiple sclerosis with MR spectroscopy at 7T: Neurochemical Profiling of MS With MRS. https://app.cochat.ai/papers/10.1002/jmri.25356
- The paper
- Prinsen, H., de Graaf, R. A., Mason, G. F., Pelletier, D., & Juchem, C. (2017). Reproducibility measurement of glutathione, GABA, and glutamate: Towards in vivo neurochemical profiling of multiple sclerosis with MR spectroscopy at 7T: Neurochemical Profiling of MS With MRS. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.25356
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.