Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 472

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Liquid chromatographic/electrospray ionization tandem mass spectrometric study of the phenolic composition of cocoa (Theobroma cacao)

Sánchez‐Rabaneda, Ferran, Jáuregui, Olga, Casals, Isidre, Andrés‐Lacueva, Cristina, Izquierdo‐Pulido, Maria, Lamuela‐Raventós, Rosa M.·2003·Journal of Mass Spectrometry

Abstract

Liquid chromatography coupled with ionspray mass spectrometry in the tandem mode (LC/MS/MS) with negative ion detection was used for the identification of a variety of phenolic compounds in a cocoa sample. Gradient elution with water and acetonitrile, both containing 0.1% HCOOH, was used. Standard solutions of 31 phenolic compounds, including benzoic and cinnamic acids and flavonoid compounds, were studied in the negative ion mode using MS/MS product ion scans. At low collisional activation, the deprotonated molecule [M − H]− was observed for all the compounds studied. For cinnamic and benzoic acids, losses of CO 2 or formation of [M − CH 3]−· in the case of methoxylated compounds were observed. However, for flavonol and flavone glycosides, the spectra present both the deprotonated molecule [M − H]− of the glycoside and the ion corresponding to the deprotonated aglycone [A − H]−. The latter ion is formed by loss of the rhamnose, glucose, galactose or arabinose residue from the glycosides. Different fragmentation patterns were observed in MS/MS experiments for flavone‐C‐glycosides which showed fragmentation in the sugar part. Fragmentation of aglycones provided characteristic ions for each family of flavonoids. The optimum LC/MS/MS conditions were applied to the characterization of a cocoa sample that had been subjected to an extraction/clean‐up procedure which involved chromatography on Sephadex LH20 and thin‐layer chromatographic monitoring. In addition to compounds described in the literature, such as epicatechin and catechin, quercetin, isoquercitrin (quercetin‐3‐O‐glucoside) and quercetin‐3‐O‐arabinose, other compounds were identified for the first time in cocoa samples, such as hyperoside (quercetin‐3‐O‐galactoside), naringenin, luteolin, apigenin and some O‐glucosides and C‐glucosides of these compounds. Copyright © 2003 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.395

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 472

Metadata

Authors
Sánchez‐Rabaneda, F., Jáuregui, O., Casals, I., Andrés‐Lacueva, C., Izquierdo‐Pulido, M., & Lamuela‐Raventós, R. M.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
2003-01
Volume
38
Issue
1
Pages
35-42
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W2036081797
Cited by
472
References
1
FWCI
31.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.