Cellular shape and pressure may mediate mechanical control of tissue composition in tendons
The DOI matches its Crossref record.
Abstract
In vivo studies have suggested that mechanical factors are involved in the regulation of the morphology and biochemical composition of tendons that wrap around bones. In these tendons fibrocartilage is found in the segment wrapped around the bone, and tendon far from the bone displays normal tendon histomorphology. Recent in vitro studies have shown that intermittently loaded connective tissue cells are sensitive to changes in cellular shape and hydrostatic pressure: stretching and distortion of the cells enhances production of fibrous matrix and hydrostatic pressure enhances production of cartilaginous matrix. We used finite‐element analysis to determine whether the regions of increased development of cartilaginous matrix in tendons that wrap around bones correspond to regions in which tendon cells are subjected to higher pressures, and whether the maintenance and rearrangement of fibrous extracellular matrix in these tendons is associated with regions of stretching and distortion of cells. We found that regions of cartilaginous matrix and fibrous matrix formation and turnover correlate well with patterns of hydrostatic compressive stress and distortional strain in the tendon. Although further experiments clearly are needed to establish the predictive value of our approach, hydrostatic stress and distortional strain history—parameters intimately related to changes in cellular pressure and shape, respectively—appear to be important tissue‐level mechanical stimuli that regulate cartilaginous and fibrous matrix composition of connective tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nature’s hierarchical materials
Fratzl, P., & Weinkamer, R. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2007.06.001 · Cited by 2,800
Fibrocartilage in tendons and ligaments — an adaptation to compressive load
BENJAMIN, M., & RALPHS, J. R. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19340481.x · Cited by 787
Mechanobiology of Skeletal Regeneration
Carter, D. R., Beaupr??, G. S., Giori, N. J., & Helms, J. A. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00006 · Cited by 758
Self-citationLotz, J. C., Colliou, O. K., Chin, J. R., Duncan, N. A., & Liebenberg, E. (1998) · Spine · doi:10.1097/00007632-199812010-00004 · Cited by 401
The role of mechanobiology in tendon healing
Killian, M. L., Cavinatto, L., Galatz, L. M., & Thomopoulos, S. (2012) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2011.11.002 · Cited by 332
Epigenetic mechanisms of character origination
Newman, S. A., & M�ller, G. B. (2000) · Journal of Experimental Zoology · doi:10.1002/1097-010x(20001215)288:4<304::aid-jez3>3.0.co;2-g · Cited by 304
Finite element models in tissue mechanics and orthopaedic implant design
Prendergast, P. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00018-1 · Cited by 255
The role of vasculature and angiogenesis for the pathogenesis of degenerative tendons disease
Pufe, T., Petersen, W. J., Mentlein, R., & Tillmann, B. N. (2005) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2005.00465.x · Cited by 246
“The contact area adjacent to the boney pulley consists of fibrocartilage (Benjamin & Evans, 1990; Tillmann & Schünke, 1991; Giore et al., 1993; Vogel et al., 1993; Benjamin et al., 1995; Koch & Tillmann, 1995; Gillard et al., 1979; Milz et al., 1998).”
BackgroundComputational Modeling of Ligament Mechanics
Weiss, J. A., & Gardiner, J. C. (2001) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v29.i3.20 · Cited by 244
Is compressive load a factor in the development of tendinopathy?
Cook, J., & Purdam, C. (2012) · British Journal of Sports Medicine · doi:10.1136/bjsports-2011-090414 · Cited by 221
Jin, M., Frank, E. H., Quinn, T. M., Hunziker, E. B., & Grodzinsky, A. J. (2001) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.2001.2543 · Cited by 214
A versatile shear and compression apparatus for mechanical stimulation of tissue culture explants
Frank, E. H., Jin, M., Loening, A. M., Levenston, M. E., & Grodzinsky, A. J. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00100-7 · Cited by 195
The Pathobiology and Repair of Tendon and Ligament Injury
Goodship, A. E., Birch, H. L., & Wilson, A. M. (1994) · Veterinary Clinics of North America: Equine Practice · doi:10.1016/s0749-0739(17)30359-0 · Cited by 189
Hannafin, J. A., Arnoczky, S. P., Hoonjan, A., & Torzilli, P. A. (1995) · Journal of Orthopaedic Research · doi:10.1002/jor.1100130615 · Cited by 175
Scaffold-Mediated Immunoengineering as Innovative Strategy for Tendon Regeneration
Russo, V., El Khatib, M., Prencipe, G., Cerveró-Varona, A., Citeroni, M. R., Mauro, A., Berardinelli, P., Faydaver, M., Haidar-Montes, A. A., Turriani, M., et al. (2022) · Cells · doi:10.3390/cells11020266 · Cited by 49
Metadata
- Authors
- Giori, N. J., Beaupré, G. S., & Carter, D. R.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1993-07
- Volume
- 11
- Issue
- 4
- Pages
- 581-591
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2027751122
- Cited by
- 190
- References
- 0
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.