Effect of stress deprivation and cyclic tensile loading on the material and morphologic properties of canine flexor digitorum profundus tendon: An in vitro study
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The effect of stress deprivation and cyclic tensile loading on the mechanical and histologic properties of the canine flexor digitorum profundus tendon was examined using an in vitro system. Stress deprivation resulted in a progressive and statistically significant decrease in the tensile modulus over an 8‐week period. Histologically, stress‐deprived tendons demonstrated quantitative changes in the morphology and number of cells and in the alignment of collagen. The change in tensile properties was not associated with an alteration in the water content of the tissue, but the change appeared to be dependent on the presence of a viable cell population. Dead (acellular) tendons did not undergo any alteration in tensile modulus in this in vitro system. In vitro cyclic tensile loading of tendons over a 4‐week time period resulted in a significant increase in the tensile modulus (93% of the control) compared with that of the stress‐deprived tendons (68% of the control). This loading regimen also maintained the normal histologic pattern of the tendons. The results of this study are similar to those previously reported for in vivo studies and suggest that this in vitro model may represent a valid system with which to test the effects of various stress conditions on the tensile properties of tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Woo, S. L., Gomez, M. A., Sites, T. J., Newton, P. O., Orlando, C. A., & Akeson, W. H. (1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769080-00014 · Cited by 388
Woo, S. L.-Y., Ritter, M. A., Amiel, D., Sanders, T. M., Gomez, M. A., Kuei, S. C., Garfin, S. R., & Akeson, W. H. (1980) · Connective Tissue Research · doi:10.3109/03008208009152109 · Cited by 338
Amiel, D., Woo, S. L.-Y., Harwood, F. L., & Akeson, W. H. (1982) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678208992224 · Cited by 233
Akeson, W. H., Woo, S. L. Y., Amiel, D., Coutts, R. D., & Daniel, D. (1973) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197306000-00039 · Cited by 203
Influence of exercise on strength of medial collateral knee ligaments of dogs
Tipton, C., James, S., Mergner, W., & Tcheng, T. (1970) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1970.218.3.894 · Cited by 190
Cellular shape and pressure may mediate mechanical control of tissue composition in tendons
Giori, N. J., Beaupré, G. S., & Carter, D. R. (1993) · Journal of Orthopaedic Research · doi:10.1002/jor.1100110413 · Cited by 190
Akeson, W. H., Amiel, D., Mechanic, G. L., Woo, S. L.-Y., Harwood, F. L., & Hamer, M. L. (1977) · Connective Tissue Research · doi:10.3109/03008207709152607 · Cited by 185
Ion channels activated by osmotic and mechanical stress in membranes of opossum kidney cells
Ubl, J. J., Murer, H., & Kolb, H. ‐. (1988) · The Journal of Membrane Biology · doi:10.1007/bf01872324 · Cited by 151
Hannafin, J. A., & ARNOCZKY, S. P. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120307 · Cited by 149
Self-citationMultiple forms of mechanosensitive ion channels in osteoblast-like cells
Davidson, R. M., Tatakis, D. W., & Auerbach, A. L. (1990) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00370609 · Cited by 148
Cited by
Wang, J. H.-C. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.011 · Cited by 1,002
Shelbourne, K. D., & Gray, T. (1997) · The American Journal of Sports Medicine · doi:10.1177/036354659702500610 · Cited by 413
Arampatzis, A., Karamanidis, K., & Albracht, K. (2007) · Journal of Experimental Biology · doi:10.1242/jeb.003814 · Cited by 354
“degeneration of the extracellular matrix) imposed by an upregulation of matrix metalloproteinases (Amiel et al., 1982; Hannafin et al., 1995; Brown et al., 1998; Arnoczky et al., 2004).”
BackgroundTendon Biomechanics and Mechanobiology—A Minireview of Basic Concepts and Recent Advancements
Wang, J. H.-C., Guo, Q., & Li, B. (2012) · Journal of Hand Therapy · doi:10.1016/j.jht.2011.07.004 · Cited by 343
The role of mechanobiology in tendon healing
Killian, M. L., Cavinatto, L., Galatz, L. M., & Thomopoulos, S. (2012) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2011.11.002 · Cited by 332
Jones, G. C., Corps, A. N., Pennington, C. J., Clark, I. M., Edwards, D. R., Bradley, M. M., Hazleman, B. L., & Riley, G. P. (2006) · Arthritis & Rheumatism · doi:10.1002/art.21672 · Cited by 292
Is compressive load a factor in the development of tendinopathy?
Cook, J., & Purdam, C. (2012) · British Journal of Sports Medicine · doi:10.1136/bjsports-2011-090414 · Cited by 221
Aligned multilayered electrospun scaffolds for rotator cuff tendon tissue engineering
Orr, S. B., Chainani, A., Hippensteel, K. J., Kishan, A., Gilchrist, C., Garrigues, N. W., Ruch, D. S., Guilak, F., & Little, D. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.06.010 · Cited by 212
“In contrast, once cells are confluent on the surface of electrospun scaffolds and lose contact with fibers, cell–cell contact may become the predominant driver of direction of cellular alignment, unless mechanical stimulation is applied to the scaffolds to maintain alignment [51,67,68].”
Kongsgaard, M., Qvortrup, K., Larsen, J., Aagaard, P., Doessing, S., Hansen, P., Kjaer, M., & Magnusson, S. P. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546509350915 · Cited by 212
“However, several authors have hypothesized that tendinopathy may arise from microrupture damage and subsequent stress deprivation of adjacent tenocytes, which eventually will elicit a catabolic tenocyte response.(1,11) Therefore, our findings of decreased mean fibril diameter, which mainly arose from a lack of small-…”
The impact of loading, unloading, ageing and injury on the human tendon
Magnusson, S. P., & Kjaer, M. (2019) · The Journal of Physiology · doi:10.1113/jp275450 · Cited by 207
“The effects of immobilization on the tendon have been studied in animal models, and they overwhelming show a decline in mechanical properties (Woo et al. 1982; Yamamoto et al. 1993; Hannafin et al. 1995; Almeida-Silveira et al. 2000; Matsumoto et al. 2003; Rumian et al. 2009).”
BackgroundArnoczky, S. P., Tian, T., Lavagnino, M., Gardner, K., Schuler, P., & Morse, P. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(02)00038-4 · Cited by 195
Self-citationArnoczky, S. P., Tian, T., Lavagnino, M., & Gardner, K. (2004) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00185-2 · Cited by 177
Self-citationLavagnino, M., Arnoczky, S. P., Tian, T., & Vaupel, Z. (2003) · Connective Tissue Research · doi:10.1080/03008200390215881 · Cited by 175
Self-citationBiocompatibility of Acellular Human Pericardium
Mirsadraee, S., Wilcox, H. E., Watterson, K. G., Kearney, J. N., Hunt, J., Fisher, J., & Ingham, E. (2007) · Journal of Surgical Research · doi:10.1016/j.jss.2007.01.026 · Cited by 104
Scaffold-Mediated Immunoengineering as Innovative Strategy for Tendon Regeneration
Russo, V., El Khatib, M., Prencipe, G., Cerveró-Varona, A., Citeroni, M. R., Mauro, A., Berardinelli, P., Faydaver, M., Haidar-Montes, A. A., Turriani, M., et al. (2022) · Cells · doi:10.3390/cells11020266 · Cited by 49
Metadata
- Authors
- Hannafin, J. A., Arnoczky, S. P., Hoonjan, A., & Torzilli, P. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1995-11
- Volume
- 13
- Issue
- 6
- Pages
- 907-914
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2048625931
- Cited by
- 175
- References
- 16
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.