Porous ceramics as bone graft substitutes in long bone defects: A biomechanical, histological, and radiographic analysis
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Three porous ceramic bone graft materials were compared with regard to their ability to heal a 2.5 cm defect created surgically in a bilateral canine radius model. The ceramic materials were analyzed at 12 and 24 weeks after surgery and included tricalcium phosphate, hydroxyapatite, and collagen hydroxyapatite, which contained a mixture of 35% tricalcium phosphate and 65% hydroxyapatite with added collagen. Each material was evaluated alone and with added bone marrow aspirate. All the implants were compared with a graft of autogenous cancellous bone in the contralateral radius. Biomechanical testing and radiographic evauation revealed that the addition of bone marrow aspirate was essential for tricalcium phosphate and hydroxyapatite to achieve results comparable with those of cancellous bone. Collagen hydroxyapatite performed well without the addition of bone marrow, although the addition of marrow did have a positive effect. Further qualitative radiographic and histological analysis demonstrated that tricalcium phosphate was the only ceramic that showed any sign of degradation at 24 weeks. This observed degradation proved to be an important factor in evaluating radiographs because the radiodensity of collagen hydroxyapatite and hydroxyapatite interfered with the determination of radiographic union. At 24 weeks, tricalcium phosphate with bone marrow was the material that performed most like cancellous bone. In this study, the biomechanical and radiographic parameters of tricalcium phosphate with bone marrow were roughly comparable with those of cancellous bone at 12 and 24 weeks. Tricalcium phosphate was the only implant that showed significant evidence of degradation at 24 weeks by both histological and radiographic evaluations, and this degradation took place only after a degree of mechanical competence necessary for weight‐bearing was achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
Morbidity at Bone Graft Donor Sites
Younger, E. M., & Chapman, M. W. (1989) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-198909000-00002 · Cited by 2,012
Tissue, cellular and subcellular events at a bone-ceramic hydroxylapatite interface.
Jarcho, M., Kay, J. F., Gumaer, K. I., Doremus, R. H., & Drobeck, H. P. (1977) · PubMed · Cited by 870
Donor site pain from the ilium. A complication of lumbar spine fusion
Summers, B., & Eisenstein, S. (1989) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.71b4.2768321 · Cited by 750
Hydroxyapatite formed from Coral Skeletal Carbonate by Hydrothermal Exchange
ROY, D. M., & LINNEHAN, S. K. (1974) · Nature · doi:10.1038/247220a0 · Cited by 667
Donor-Site Morbidity after Harvesting Rib and Iliac Bone
Laurie, S. W. S., Kaban, L. B., Mulliken, J. B., & Murray, J. E. (1984) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198406000-00014 · Cited by 647
Bone Regeneration Within a Coralline Hydroxyapatite Implant
Holmes, R. E. (1979) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-197905000-00004 · Cited by 438
Repair of bone defects with marrow cells and porous ceramic: Experiments in rats
Ohgushi, H., Goldberg, V. M., & Caplan, A. I. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909149289 · Cited by 367
Hydroxyapatite and Tricalcium Phosphate Bone Graft Substitutes
Bucholz, R. W., Carlton, A., & Holmes, R. E. (1987) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)30395-3 · Cited by 363
The Biochemistry and Physiology of Bone
Chalmers, J. (1973) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.55b2.444 · Cited by 354
Cited by
Giannoudis, P. V., Dinopoulos, H., & Tsiridis, E. (2005) · Injury · doi:10.1016/j.injury.2005.07.029 · Cited by 2,078
THE ROLE OF GROWTH FACTORS IN THE REPAIR OF BONE: BIOLOGY AND CLINICAL APPLICATIONS
LIEBERMAN, J. R., DALUISKI, A., & EINHORN, T. A. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200206000-00022 · Cited by 932
Fernandez de Grado, G., Keller, L., Idoux-Gillet, Y., Wagner, Q., Musset, A.-M., Benkirane-Jessel, N., Bornert, F., & Offner, D. (2018) · Journal of Tissue Engineering · doi:10.1177/2041731418776819 · Cited by 912
BRUDER, S. P., KRAUS, K. H., GOLDBERG, V. M., & KADIYALA, S. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199807000-00007 · Cited by 877
Collagen-Hydroxyapatite Composites for Hard Tissue Repair
Department of Materials, U. O. O., Wahl, D., & Czernuszka, J. (2006) · European Cells and Materials · doi:10.22203/ecm.v011a06 · Cited by 675
Osteoconduction at porous hydroxyapatite with various pore configurations
Chang, B.-S., Lee, >. K. >.-K., Hong, K.-S., Youn, H.-J., Ryu, H.-S., Chung, S.-S., & Park, K.-W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00030-2 · Cited by 635
Mesenchymal Stem Cells in Osteobiology and Applied Bone Regeneration
Bruder, S. P., Jaiswal, N., Ricalton, N. S., Mosca, J. D., Kraus, K. H., & Kadiyala, S. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00025 · Cited by 436
Bone reconstruction: from bioceramics to tissue engineering
El-Ghannam, A. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.1.87 · Cited by 415
Porous calcium polyphosphate scaffolds for bone substitute applications — in vitro characterization
Pilliar, R. M., Filiaggi, M. J., Wells, J. D., Grynpas, M. D., & Kandel, R. A. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00261-1 · Cited by 359
Limitations of Autograft and Allograft: New Synthetic Solutions
Betz, R. R. (2002) · Orthopedics · doi:10.3928/0147-7447-20020502-04 · Cited by 335
Tissue Engineering of Bone: Cell Based Strategies
Bruder, S. P., & Fox, B. S. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199910001-00008 · Cited by 324
Characterization of a bovine collagen–hydroxyapatite composite scaffold for bone tissue engineering
Rodrigues, C. V. M., Serricella, P., Linhares, A. B. R., Guerdes, R. M., Borojevic, R., Rossi, M. A., Duarte, M. E. L., & Farina, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00410-1 · Cited by 322
REPAIR OF CRANIOTOMY DEFECTS USING BONE MARROW STROMAL CELLS
Krebsbach, P. H., Mankani, M. H., Satomura, K., Kuznetsov, S. A., & Robey, P. G. (1998) · Transplantation · doi:10.1097/00007890-199811270-00002 · Cited by 279
Yuan, J., Cui, L., Zhang, W. J., Liu, W., & Cao, Y. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.10.015 · Cited by 218
den Boer, F. C., Wippermann, B. W., Blokhuis, T. J., Patka, P., Bakker, F. C., & Haarman, H. J. T. M. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(02)00205-x · Cited by 187
Current Understanding of Osteoconduction in Bone Regeneration
Cornell, C. N., & Lane, J. M. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00027 · Cited by 173
Sciadini, M. F., & Johnson, K. D. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180218 · Cited by 168
Self-citationOSTEOCONDUCTIVE MATERIALS AND THEIR ROLE AS SUBSTITUTES FOR AUTOGENOUS BONE GRAFTS
Cornell, C. N. (1999) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(05)70112-7 · Cited by 167
Lei, X., Gao, J., Xing, F., Zhang, Y., Ma, Y., & Zhang, G. (2019) · Regenerative Biomaterials · doi:10.1093/rb/rbz026 · Cited by 49
Metadata
- Authors
- Johnson, K. D., Frierson, K. E., Keller, T. S., Cook, C., Scheinberg, R., Zerwekh, J., Meyers, L., & Sciadini, M. F.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1996-05
- Volume
- 14
- Issue
- 3
- Pages
- 351-369
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2019425735
- Cited by
- 246
- References
- 26
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.