Uniaxial yield strains for bovine trabecular bone are isotropic and asymmetric
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Although evidence suggests that yield strains for trabecular bone are isotropic, i.e., independent of loading direction, decisive support for this hypothesis has remained elusive. To explicitly test whether yield strains for trabecular bone are isotropic, compressive and tensile yield strains of 51 specimens of bovine tibial trabecular bone (0.41 ± 0.08 g/cm 3 [mean apparent density ± SD]) were measured without end artifacts in on‐axis (along the principal trabecular orientation) and off‐axis (30–40° oblique to on‐axis) orientations. Yield strains for the on‐axis and off‐axis orientations were similar in tension (0.80 ± 0.03% compared with 0.85 ± 0.04%, p = 0.21) and compression (0.97 ± 0.05% compared with 0.96 ± 0.07%, p > 0.99); as expected, modulus and strength depended on loading direction. When considered with an ancillary experiment on bovine tibial trabecular bone that showed yield strains to be similar between on‐axis and 90° off‐axis bone, these results firmly establish the isotropy of uniaxial yield strains for bovine tibial trabecular bone. This bone is of high density and has a strong, plate‐type, anisotropic architecture. Therefore, yield strains for uniaxial loading are expected to be isotropic, or nearly so, for other types of dense trabecular bone, although further work is required to confirm this and to establish this behavior for bone of lower density.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“High-density trabecular bone, such as that from the human femoral neck and bovine proximal tibia, tends to have isotropic yield strains (97, 98).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [97]
In the citing paper
“Ultimate strains in trabecular bone also appear to be isotropic and range from 1.0% to 2.5% (97, 99), whereas yield strains range from 0.70% to 0.77% in compression and from 0.65% to 0.71% in tension (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [97]
Citations
Cites
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932 · cited 2×
“Because the micromechanics and failure mechanisms of individual trabeculae depend on architecture and apparent density (8,14,16,22), extension of the trends reported here to such bone requires further”
Yield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653
Self-citationMosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Systematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377
Self-citationKeaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationFracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 309
Trabecular bone exhibits fully linear elastic behavior and yields at low strains
Keaveny, T. M., Guo, X. E., Wachtel, E. F., McMahon, T. A., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90053-1 · Cited by 300
Self-citationMechanical Property Distributions in the Cancellous Bone of the Human Proximal Femur
Brown, T. D., & Ferguson, A. B. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990819 · Cited by 282
Tensile and compressive properties of cancellous bone
Røhl, L., Larsen, E., Linde, F., Odgaard, A., & Jørgensen, J. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90006-9 · Cited by 279
The underestimation of Young's modulus in compressive testing of cancellous bone specimens
Odgaard, A., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90333-i · Cited by 225
Failure mechanisms in human vertebral cancellous bone
Fyhrie, D. P., & Schaffler, M. B. (1994) · Bone · doi:10.1016/8756-3282(94)90900-8 · Cited by 215
Cheal, E. J., Spector, M., & Hayes, W. C. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100314 · Cited by 213
Role of trabecular morphology in the etiology of age-related vertebral fractures
Snyder, B. D., Piazza, S., Edwards, W. T., & Hayes, W. C. (1993) · Calcified Tissue International · doi:10.1007/bf01673396 · Cited by 164
Ford, C. M., & Keaveny, T. M. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00062-0 · Cited by 158
Self-citationTheoretical analysis of the experimental artifact in trabecular bone compressive modulus
Keaveny, T. M., Borchers, R. E., Gibson, L. J., & Hayes, W. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90021-6 · Cited by 136
Self-citationYield Behavior of Bovine Cancellous Bone
Turner, C. H. (1989) · Journal of Biomechanical Engineering · doi:10.1115/1.3168375 · Cited by 127
Morphological and structural characteristics of the proximal femur in human and rat
Bagi, C. M., Wilkie, D. P., Georgelos, K., Williams, D., & Bertolini, D. R. (1997) · Bone · doi:10.1016/s8756-3282(97)00121-x · Cited by 119
Material properties of femoral cancellous bone in axial loading: Part I: Time independent properties
Rohlmann, A., Zilch, H., Bergmann, G., & Kölbel, R. (1980) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00450930 · Cited by 115
The distribution and anisotropy of the stiffness of cancellous bone in the human patella
Townsend, P. R., Raux, P., Rose, R. M., Miegel, R. E., & Radin, E. L. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90071-8 · Cited by 113
Elastic moduli, yield stress, and ultimate stress of cancellous bone in the canine proximal femur
Vahey, J. W., Lewis, J. L., & Vanderby, R. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90264-8 · Cited by 81
The scanning electron microscope in studies of trabecular bone from a human vertebral body.
Whitehouse, W. J., Dyson, E. D., & Jackson, C. (1971) · PubMed Central · Cited by 77
Trabecular bone remodeling around smooth and porous implants in an equine patellar model
Cheal, E. J., Snyder, B. D., Nunamaker, D. M., & Hayes, W. C. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90029-7 · Cited by 61
Density and Temperature Effects on Some Mechanical Properties of Cancellous Bone
Brear, K., Currey, J. D., Raines, S. A., & Smith, K. (1988) · Engineering in Medicine · doi:10.1243/emed_jour_1988_017_043_02 · Cited by 55
Mechanistic Approaches to Analysis of Trabecular Bone
Keaveny, P. D. T. M. (1998) · Forma · Cited by 39
Is yield strain in cancellous bone isotropic?
Turner, C. H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)90059-4 · Cited by 4
Turner, C. H. (1989) · Journal of Biomechanical Engineering · doi:10.1115/1.3168387 · Cited by 4
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)90060-8 · Cited by 2
Self-citation
Research works printed but not linked: 2
- 10.1016/0021-9290(93)90021-6 · DOI
- Keaveny TM, 1994, Yield strains for bovine trabecular bone are isotropic but asymmetric, Trans Orthop Res Soc, 19, 428
Cited by
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“High-density trabecular bone, such as that from the human femoral neck and bovine proximal tibia, tends to have isotropic yield strains (97, 98).”
Biomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Self-citationDependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Self-citationSchileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
“, 2003; Taylor, 2003), there is a growing consensus on the substantial isotropy of yield strain and on its invariance to density (Bayraktar et al., 2004b; Chang et al., 1999; Cowin and He, 2005; Currey, 2004; Kopperdahl and Keaveny, 1998), and a strain-based criteria managed to well fit mono- and multi-axial experimen…”
BackgroundInfluential
Metadata
- Authors
- Chang, W. C. W., Christensen, T. M., Pinilla, T. P., & Keaveny, T. M.
- Affiliations
- University of California, Berkeley (US)
- University of California, San Francisco (US)
- Corresponding author
- Chang, Wesley C. W.
- Christensen, Tennille M.
- ORCID
- Keaveny, Tony M.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1999-07
- Volume
- 17
- Issue
- 4
- Pages
- 582-585
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2003769430
- Cited by
- 77
- References
- 27
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 4 · 2019: 1 · 2018: 4 · 2016: 2 · 2015: 4 · 2014: 4 · 2013: 2 · 2012: 2
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-43784, R01AR043784)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, yield strain, isotropy, anisotropy, bovine tibia, uniaxial loading, trabecular orientation, bone mechanical properties
- MeSH terms
- Animals, Biomechanical Phenomena, Cattle, Tibia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.