CoChat

Low‐magnitude high‐frequency mechanical signals accelerate and augment endochondral bone repair: Preliminary evidence of efficacy

Open access
Goodship, Allen E., Lawes, Timothy J., Rubin, Clinton T. · 2009 · Journal of Orthopaedic Research
Cited by 103

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Fracture healing can be enhanced by load bearing, but the specific components of the mechanical environment which can augment or accelerate the process remain unknown. The ability of low‐magnitude, high‐frequency mechanical signals, anabolic in bone tissue, are evaluated here for their ability to influence fracture healing. The potential for short duration (17 min), extremely low‐magnitude (25 µm), high‐frequency (30 Hz) interfragmentary displacements to enhance fracture healing was evaluated in a mid‐diaphyseal, 3‐mm osteotomy of the sheep tibia. In a pilot study of proof of concept and clinical relevance, healing in osteotomies stabilized with rigid external fixation (Control: n = 4), were compared to the healing status of osteotomies with the same stiffness of fixation, but supplemented with daily mechanical loading (Experimental: n = 4). These 25‐µm displacements, induced by a ferroactive shape‐memory alloy (“smart” material) incorporated into the body of the external fixator, were less than 1% of the 3‐mm fracture gap, and less than 6% of the 0.45‐mm displacement measured at the site during ambulation (p < 0.001). At 10‐weeks post‐op, the callus in the Experimental group was 3.6‐fold stiffer (p < 0.03), 2.5‐fold stronger (p = 0.05), and 29% larger (p < 0.01) than Controls. Bone mineral content was 52% greater in the Experimental group (p < 0.02), with a 2.6‐fold increase in bone mineral content (BMC) in the region of the periosteum (p < 0.001). These data reinforce the critical role of mechanical factors in the enhancement of fracture healing, and emphasize that the signals need not be large to be influential and potentially clinically advantageous to the restoration of function. © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27: 922–930, 2009

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jor.20824

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 103

Metadata

Authors
Goodship, A. E., Lawes, T. J., & Rubin, C. T.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
2008-12-30
Volume
27
Issue
7
Pages
922-930
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2053217141
Cited by
103
References
3
FWCI
4.82
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.