Low‐magnitude high‐frequency mechanical signals accelerate and augment endochondral bone repair: Preliminary evidence of efficacy
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Fracture healing can be enhanced by load bearing, but the specific components of the mechanical environment which can augment or accelerate the process remain unknown. The ability of low‐magnitude, high‐frequency mechanical signals, anabolic in bone tissue, are evaluated here for their ability to influence fracture healing. The potential for short duration (17 min), extremely low‐magnitude (25 µm), high‐frequency (30 Hz) interfragmentary displacements to enhance fracture healing was evaluated in a mid‐diaphyseal, 3‐mm osteotomy of the sheep tibia. In a pilot study of proof of concept and clinical relevance, healing in osteotomies stabilized with rigid external fixation (Control: n = 4), were compared to the healing status of osteotomies with the same stiffness of fixation, but supplemented with daily mechanical loading (Experimental: n = 4). These 25‐µm displacements, induced by a ferroactive shape‐memory alloy (“smart” material) incorporated into the body of the external fixator, were less than 1% of the 3‐mm fracture gap, and less than 6% of the 0.45‐mm displacement measured at the site during ambulation (p < 0.001). At 10‐weeks post‐op, the callus in the Experimental group was 3.6‐fold stiffer (p < 0.03), 2.5‐fold stronger (p = 0.05), and 29% larger (p < 0.01) than Controls. Bone mineral content was 52% greater in the Experimental group (p < 0.02), with a 2.6‐fold increase in bone mineral content (BMC) in the region of the periosteum (p < 0.001). These data reinforce the critical role of mechanical factors in the enhancement of fracture healing, and emphasize that the signals need not be large to be influential and potentially clinically advantageous to the restoration of function. © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27: 922–930, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regulation of bone formation by applied dynamic loads.
Rubin, C. T., & Lanyon, L. E. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00012 · Cited by 1,558
Self-citationControlled mechanical stimulation in the treatment of tibial fractures
KENWRIGHT, J., & GOODSHIP, A. E. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198904000-00006 · Cited by 373
Self-citationRubin, C. T., Capilla, E., Luu, Y. K., Busa, B., Crawford, H., Nolan, D. J., Mittal, V., Rosen, C. J., Pessin, J. E., & Judex, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708467104 · Cited by 274
Self-citation
Cited by
Chen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398
Mechanical signals as anabolic agents in bone
Ozcivici, E., Luu, Y. K., Adler, B., Qin, Y.-X., Rubin, J., Judex, S., & Rubin, C. T. (2010) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2009.239 · Cited by 441
Self-citationKelly, D. J., & Jacobs, C. R. (2010) · Birth Defects Research Part C: Embryo Today: Reviews · doi:10.1002/bdrc.20173 · Cited by 234
Wehrle, E., Wehner, T., Heilmann, A., Bindl, R., Claes, L., Jakob, F., Amling, M., & Ignatius, A. (2014) · Journal of Orthopaedic Research® · doi:10.1002/jor.22629 · Cited by 59
“3g(12,13,15) or in sheep using 35Hz and 20mm interfragmentary movements (IFM).(10) Other studies did not find major influences on bone repair using vibrations of 35–90Hz/0.”
BackgroundInfluentialConcepts and clinical aspects of active implants for the treatment of bone fractures
Ganse, B., Orth, M., Roland, M., Diebels, S., Motzki, P., Seelecke, S., Kirsch, S.-M., Welsch, F., Andres, A., Wickert, K., et al. (2022) · Acta Biomaterialia · doi:10.1016/j.actbio.2022.05.001 · Cited by 37
Barcik, J., & Epari, D. R. (2021) · Biomedicines · doi:10.3390/biomedicines9060691 · Cited by 28
Metadata
- Authors
- Goodship, A. E., Lawes, T. J., & Rubin, C. T.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2008-12-30
- Volume
- 27
- Issue
- 7
- Pages
- 922-930
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2053217141
- Cited by
- 103
- References
- 3
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.