Cited by 33Analytical chemistry methods developmentPesticide Residue Analysis and SafetyIonic liquids properties and applications

Temperature‐controlled ionic liquid‐dispersive liquid‐phase microextraction for preconcentration of chlorotoluron, diethofencarb and chlorbenzuron in water samples

Open access
Zhou, Qingxiang, Zhang, Xiaoguo, Xie, Guohong, Xiao, Junping·2009·Journal of Separation Science

Abstract

This article describes a new, rapid and sensitive method for the determination of chlorotoluron, diethofencarb and chlorbenzuron from water samples with temperature‐controlled ionic liquid‐dispersive liquid‐phase microextraction. In the preconcentration procedure, ionic liquid 1‐hexyl‐3‐methylimidazolium hexafluorophosphate [C 6 MIM] [PF 6] was employed as the extraction solvent. The parameters, such as volume of [C 6 MIM] [PF 6], sample pH, extraction time, centrifuging time, temperature and salting‐out effect, were investigated in detail. Under the optimal extraction conditions, it has been found that three analytes had excellent LODs (S/N=3) in the range of 0.04–0.43 μg/L. The RSDs (n=6) were in the range of 1.3–4.7%. The proposed method was evaluated with lake water, tap water and melted snow water samples. The experimental results indicated that the proposed method had excellent prospect and would be widely used in the future.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jssc.200900444

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In four IL-DLLME pesticide works, no disperser solvent was used (only the IL [HMIm][PF6]), because dispersion is temperature-assisted.

    “We should mention that, in four of these works [13-16], no disperser solvent was used (only the IL [HMIm][PF6]), since the dispersion is temperature-assisted.”
  • For IL-DLLME of pesticides, a relatively small number of works has been published, especially in recent years.

    “Regarding IL-DLLME of pesticides, a relatively small number of works has come out, especially in recent years [13-16,32,38,47,50].”
  • The temperature-controlled LPME variation has been applied using only ionic liquids as extractants.

    “This variation of the technique has been applied using only ionic liquids (ILs) as extractants [13-16]”
  • In most IL-DLLME pesticide works, water samples were analyzed using HPLC as the separation technique.

    “In most cases, water samples have also been analyzed using HPLC as the separation technique [13-16,32,47].”
  • IL-DLLME has a drawback of a wide peak at the beginning of the chromatogram corresponding to the IL.

    “As can be seen, at the beginning of the chromatogram, there appeared a wide peak, corresponding to the IL - one of the main drawbacks of using IL-DLLME, as already reported [14-19,32,38,47,50,65-67] -although, in this case, it did not interfere at all in the separation.”

    From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [15]

    The Introduction discusses drawbacks of ionic liquids, but names cost and difficulty of synthesis, not a chromatographic peak. The Instrument section describes the HPLC setup without reporting a wide peak at the start of a chromatogram. Searches for an IL peak, chromatograms, and interference found no passage addressing the claimed drawback. (LLM, conf=0.73)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 34

  1. Blanco, M. C. L., Cid, S. B., Grande, B. C., Gandara, J. S., J. Chromatogr. A 2003, 984, 245-252.
  2. Sanagi, M. M., See, H. H., Ibrahim, W. A. W., Naim, A. A., J. Chromatogr. A 2004, 1059, 95-101.
  3. Baggiani, C., Baravalle, P., Giraudi, G., Tozzi, C., J. Chromatogr. A 2007, 1141, 158-164.
  4. Charlton, A. J. A., Jones, A., J. Chromatogr. A 2007, 1141, 117-122.
  5. Pan, H. J., Ho, W. H., Anal. Chim. Acta 2004, 527, 61-67.
  6. Fatoki, O. S., Awofolu, R. O., J. Chromatogr. A 2003, 983, 225-236.
  7. Pozo, O. J., Marin, J. M., Sancho, J. V., J. Chromatogr. A 2003, 992, 133-140.
  8. Jimenez, J. J., Bernal, J. L., del Nozal, M. J., Rivera, J.M., J. Chromatogr. A 1997, 778, 289-300.
  9. S ˇtajnbaher, D., Zupanc ˇic ˇ-Kralj, L., J. Chromatogr. A. 2003, 1015, 185-198.
  10. Arthur, C. L., Pawliszyn, J., Anal Chem 1990, 62, 2145-2148.
  11. Prosen, H., Kralj, L. Z., Trends Anal. Chem. 1999, 18, 272-282.
  12. Liu, H., Dasgupta, P. K., Anal. Chem. 1996, 68, 1817-1821.
  13. Theis, A. L., Waldack, A. J., Hansen, S. M., Jeannot, M. A., Anal. Chem. 2001, 73, 5651-5654.
  14. Jeannot, M. A., Cantwell, F. F., Anal. Chem. 1997, 69, 235-239.
  15. Pedersen-Bjergaard, S., Rasmussen, K. E., Anal. Chem. 1999, 71, 2650-2656.
  16. de Jager, L. S., Andrews, A. R. J., Chromatographia 1999, 50, 733-738.
  17. de Jager, L. S., Andrews, A. R. J., Analyst 2000, 125, 1943-1948.
  18. Shen, G., Lee, H. K., Anal. Chem. 2002, 74, 648-654.
  19. Ligor, T., Buszewski, B., Chromatographia 2000, 51, S279-S282.
  20. Buszewski, B., Ligor, T., LC GC Eur 2002, 15, 92-97.
  21. Fattahi, N., Assadi, Y., Hosseini, M. R. M., Jahromi, E. Z., J. Chromatogr. A 2007, 1157, 23-29.
  22. Rezaee, M., Assadi, Y., Hosseini, M. R. M., Aghaee, E., Ahmadi, F., Berijani, S., J. Chromatogr. A 2006, 1116, 1-9.
  23. Nagaraju, D., Huang, S. D., J. Chromatogr. A 2007, 1161, 89-97.
  24. Shi, Y. A., Chen, M. Z., Muniraj, S., Jen, J. F., J. Chro- matogr. A 2008, 1207, 130-135.
  25. Peng, J. F., Liu, J. F., Jiang, G. B., Tai, C., Huang, M. J., J. Chromatogr. A 2005, 1072, 3-6.
  26. Manzoori, J. L., Amjadi, M., Abulhassani, J., Talanta. 2009, 77, 1539-1544.
  27. Welton, T., Chem. Rev. 1999, 99, 2071-2084.
  28. Liu, J., Jonsson, J. A., Jiang, G., Trends Anal. Chem. 2005, 24, 20-25.
  29. Stepnowski, P., Int. J. Mol. Sci. 2006, 7, 497-509.
  30. Liu, J. F., Jiang, G. B., Chi, Y. G., Cai, Y. Q., Zhou, Q. X., Hu, J. T., Anal. Chem. 2003, 75, 5870-5876.
  31. Vidal, L., Psillakis, E., Domini, C. E., Grane ´, N., Marken, F., Canals, A., Anal. Chim. Acta 2007, 584, 189-195.
  32. Branco, L. C., Crespo, J. G., Afonso, C. A. M., Angew Chem. Chem. Int. Ed. 2002, 41, 2771-2773.
  33. Marce, R. M., Borrull, F., J. Chromatogr. A 2000, 885, 273-290.
  34. Zhu, L., Tay, C. B., Lee, H. K., J. Chromatogr. A 2002, 963, 239-248.

Cited by

Sorted by citations

Authors
Zhou, Q., Zhang, X., Xie, G., & Xiao, J.
Affiliations
  • Henan Normal University (CN)
  • Henan Institute of Science and Technology (CN)
  • University of Science and Technology Beijing (CN)
Corresponding author
Zhou, Qingxiang
Venue
Journal of Separation Science
Publisher
Wiley
Published
2009-11
Volume
32
Issue
22
Pages
3945-3950
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W1977410162
Cited by
33
References
34
Citations by year
2023: 1 · 2022: 1 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 3 · 2014: 3 · 2013: 2 · 2012: 7
FWCI
5.12
Type
journal article
Language
en
Open access
Locations
  • Journal of Separation Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (020877022)
  • High-Tech Research & Development Planning (2006AA06Z424)
  • Personal Innovation Foundation of Universities in Henan Province
  • Natural Science Foundation of Henan Province (092300410126)
  • Fund of Henan Normal University (2006PL06)
  • Henan Key Laboratory for environmental pollution control
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
  • Physical Sciences › Chemical Engineering › Catalysis › Ionic liquids properties and applications
Keywords
ionic liquids, chlortoluron, diethofencarb, water samples, 1-hexyl-3-methylimidazolium hexafluorophosphate, salting-out, lake water, tap water, snowmelt water
MeSH terms
Chlorobenzenes, Hydrogen-Ion Concentration, Imides, Ions, Phenylurea Compounds, Temperature, Water Pollutants, Chemical, Phenylcarbamates, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review