Up‐and‐down shaker‐assisted ionic liquid‐based dispersive liquid—liquid microextraction of benzophenone‐type ultraviolet filters
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Sun protection is an important part of our lives. UV filters are widely used to absorb solar radiation in sunscreens. However, excess UV filters constitute persistent groups of organic micropollutants present in the environment. An environmentally friendly ionic‐liquid‐based up‐and‐down shaker‐assisted dispersive liquid−liquid microextraction device combined with ultra‐performance liquid chromatography coupled with photodiode‐array detection has been developed to preconcentrate three UV filters (benzophenone, 2‐hydroxy‐4‐methoxybenzophenone, 2,2′‐dihydroxy‐4‐methoxybenzophenone) from field water samples. In this method, the optimal conditions for the proposed extraction method were: 40 μL [C 8 MIM][PF 6] as extraction solvent and 200 μL methanol as disperser solvent were used to extract the UV filters. After up‐and‐down shaking for 3 min, the aqueous solution was centrifuged at 5000 rpm speed, then using microtube to collect the settled extraction solvent and using ultra‐performance liquid chromatography for further analysis. Quantification results indicated that the linear range was 2–1000 ng/mL. The LOD of this method was in the range 0.2–1.3 ng/mL with r2 ≥ 0.9993. The relative recovery in studies of different types of field water samples was in the range 92–120%, and the RSD was 2.3–7.1%. The proposed method was also applied to the analysis of field samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Occurrence of some organic UV filters in wastewater, in surface waters, and in fish from Swiss lakes
Balmer, M. E., Buser, H.-R., Müller, M. D., & Poiger, T. (2005) · Environmental Science & Technology · doi:10.1021/es040055r · Cited by 779
Liu, Y., Zhao, E., Zhu, W., Gao, H., & Zhou, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.076 · Cited by 301
He, L., Luo, X., Xie, H., Wang, C., Jiang, X., & Lu, K. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.09.044 · Cited by 212
Yao, C., & Anderson, J. L. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3078-0 · Cited by 204
Lambropoulou, D. A., Giokas, D. L., Sakkas, V. A., Albanis, T. A., & Karayannis, M. I. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00781-1 · Cited by 177
Ravelo-Pérez, L. M., Hernández-Borges, J., Asensio-Ramos, M., & Rodríguez-Delgado, M. Á. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.08.012 · Cited by 156
One-step in-syringe ionic liquid-based dispersive liquid–liquid microextraction
Cruz-Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.07.040 · Cited by 154
Direct Coupling of Ionic Liquid Based Single-Drop Microextraction and GC/MS
Aguilera-Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2008) · Analytical Chemistry · doi:10.1021/ac071555g · Cited by 144
Chisvert, A., Román, I. P., Vidal, L., & Canals, A. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.12.078 · Cited by 112
Cited by
Rykowska, I., Ziemblińska, J., & Nowak, I. (2018) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.03.043 · Cited by 353
Ionic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276
“have reported the use of an up-and down-shaker as a stirring device in the determination of UV filters from waters using IL-DLLME [90], as a simpler alternative to microwaves, ultrasound, or even vortex.”
MethodBeyond dispersive liquid–liquid microextraction
Leong, M.-I., Fuh, M.-R., & Huang, S.-D. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.02.021 · Cited by 241
Self-citationRecent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232
“The method has been mainly used for the determination of organic compounds [89–98, 100–110].”
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Metadata
- Authors
- Ku, Y., Leong, M., Wang, W., & Huang, S.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2013-03-12
- Volume
- 36
- Issue
- 8
- Pages
- 1470-1477
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2161544794
- Cited by
- 32
- References
- 13
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Up‐and‐down shaker‐assisted ionic liquid‐based dispersive liquid—liquid microextraction of benzophenone‐type ultraviolet filters. https://app.cochat.ai/papers/10.1002/jssc.201201108
- The paper
- Ku, Y., Leong, M., Wang, W., & Huang, S. (2013). Up‐and‐down shaker‐assisted ionic liquid‐based dispersive liquid—liquid microextraction of benzophenone‐type ultraviolet filters. Journal of Separation Science. https://doi.org/10.1002/jssc.201201108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.