Open tubular capillary column for the separation of cytochrome C tryptic digest in capillary electrochromatography
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
A silica capillary of 50 μm internal diameter and 500 mm length (416 mm effective length) was chemically modified with 4‐(trifluoromethoxy) phenyl isocyanate in the presence of dibutyl tin dichloride as catalyst. Sodium diethyl dithiocarbamate was reacted with the terminal halogen of the bound ligand to incorporate the initiator moiety, and in situ polymerization was performed using a monomer mixture of styrene, N‐phenylacrylamide, and methacrylic acid. The resultant open tubular capillary column immobilized with the copolymer layer was used for the separation of tryptic digest of cytochrome C in capillary electrochromatography. The sample was well eluted and separated into many components. The elution patterns of tryptic digest of cytochrome C were studied with respect to pH and water content in the mobile phase. This preliminary study demonstrates that open tubular capillary electrochromatography columns with a modified copolymer layer composed of proper nonpolar and polar units fabricated by reversible addition‐fragmentation transfer polymerization can be useful as separation media for proteomic analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Another example is capillary electrochromatography that has been successfully applied for the separation of peptides138,139.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [138]
Citations
Cites
Perrier, S., & Takolpuckdee, P. (2005) · Journal of Polymer Science Part A: Polymer Chemistry · doi:10.1002/pola.20986 · Cited by 1,130
Wu, R., Hu, L., Wang, F., Ye, M., & Zou, H. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.09.022 · Cited by 257
Fast liquid chromatography: The domination of core?shell and very fine particles
Fekete, S., Olh, E., & Fekete, J. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.09.050 · Cited by 251
Preparation of monolithic silica columns for high-performance liquid chromatography
Núñez, O., Nakanishi, K., & Tanaka, N. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.029 · Cited by 234
Recent developments in the field of monolithic stationary phases for capillary electrochromatography
Svec, F. (2005) · Journal of Separation Science · doi:10.1002/jssc.200400086 · Cited by 217
Current and future trends in UHPLC
Fekete, S., Schappler, J., Veuthey, J.-L., & Guillarme, D. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.08.007 · Cited by 195
Moradian, A., Kalli, A., Sweredoski, M. J., & Hess, S. (2014) · PROTEOMICS · doi:10.1002/pmic.201300256 · Cited by 161
Fekete, S., Veuthey, J.-L., & Guillarme, D. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.03.024 · Cited by 160
Urban, J., Svec, F., & Fréchet, J. M. J. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.10.100 · Cited by 160
Yue, G., Luo, Q., Zhang, J., Wu, S.-L., & Karger, B. L. (2007) · Analytical Chemistry · doi:10.1021/ac061411m · Cited by 156
Cited by
Recent developments in capillary and microchip electroseparations of peptides (2011–2013)
Kašička, V. (2014) · ELECTROPHORESIS · doi:10.1002/elps.201300331 · Cited by 130
Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112
Ahmed, M. A., Felisilda, B. M. B., & Quirino, J. P. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.08.016 · Cited by 72
Capillary zone electrophoresis-mass spectrometry for bottom-up proteomics
Zhang, Z., Qu, Y., & Dovichi, N. J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.008 · Cited by 61
Recent developments in capillary and microchip electroseparations of peptides (2015–mid 2017)
Kašička, V. (2017) · Electrophoresis · doi:10.1002/elps.201700295 · Cited by 53
Capillary electrochromatography of proteins and peptides (2006–2015)
Mikšík, I. (2016) · Journal of Separation Science · doi:10.1002/jssc.201600908 · Cited by 47
Zhang, Z., Peuchen, E. H., & Dovichi, N. J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01147 · Cited by 29
Jiang, Z., Qu, J., Tian, X., Huo, X., Zhang, J., Guo, X., & Fang, L. (2019) · Journal of Separation Science · doi:10.1002/jssc.201900071 · Cited by 27
Advances in stimuli-responsive polymeric coatings for open-tubular capillary electrochromatography
Qi, L., & Qiao, J. (2022) · Journal of Chromatography A · doi:10.1016/j.chroma.2022.462957 · Cited by 21
Ali, A., & Cheong, W. J. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700242 · Cited by 13
Self-citationMultiplex immunoassays using surface modification-mediated porous layer open tubular capillary
Song, X., Nie, R., Liu, X., Chen, Y., & Yang, L. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.04.009 · Cited by 13
Bu, Z., Si, Q., Lu, X., Wang, P., Wu, D., & Mei, Y. (2025) · Microchimica Acta · doi:10.1007/s00604-025-07142-9 · Cited by 10
Mixed‐mode open tubular column for peptide separations by capillary electrochromatography
Ali, F., ALOthman, Z. A., & Al‐Shaalan, N. H. (2021) · Journal of Separation Science · doi:10.1002/jssc.202100116 · Cited by 10
Self-citationAli, F., & Cheong, W. J. (2016) · Bulletin of the Korean Chemical Society · doi:10.1002/bkcs.10859 · Cited by 9
Self-citationSun, G., Tang, W., Lu, Y., & Row, K. H. (2021) · Electrophoresis · doi:10.1002/elps.202100136 · Cited by 9
Ali, F., Cheong, W. J., Rafique, A., ALOthman, Z. A., Sadia, M., & Muhammad, M. (2021) · Journal of Separation Science · doi:10.1002/jssc.202100001 · Cited by 9
Self-citationSun, G., & Lu, Y. (2020) · Journal of Separation Science · doi:10.1002/jssc.202000862 · Cited by 6
Şarkaya, K. (2018) · Hacettepe University Institutional Repository (hacettepe.edu.tr) · Cited by 1
Capillary Electrochromatography
Yan, C., Wang, Y., & Xue, Y. (2016) · Wiley eBooks · doi:10.1002/9780470027318.a9434
Metadata
- Authors
- Ali, F., & Cheong, W. J.
- Affiliations
- Inha University (KR)
- Corresponding author
- Cheong, Won Jo
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2015-09-18
- Volume
- 38
- Issue
- 20
- Pages
- 3645-3654
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W1897019719
- Cited by
- 18
- References
- 51
- Citations by year
- 2025: 1 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 3 · 2018: 2 · 2017: 3 · 2016: 3
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Research Foundation of Korea (NRF)
- Ministry of Science ((2013R1A2A2A01067201))
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- open tubular capillary columns, capillary electrochromatography, cytochrome c, tryptic digest, in situ polymerization, RAFT polymerization, mobile phase pH
- MeSH terms
- Animals, Cattle, Silicon Dioxide, Trypsin, Molecular Structure, Cytochromes c, Capillary Electrochromatography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.