Simplified capillary isoelectric focusing with chemical mobilization for intact protein analysis
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
We report a capillary isoelectric focusing system based on a sequential injection method for simplified chemical mobilization. This system was coupled to an ion trap mass spectrometer with an electrokinetically pumped nanoelectrospray interface. The nanoelectrospray emitter employed an acidic sheath electrolyte. To simplify focusing and mobilization, a plug of ammonium hydroxide was first injected into the capillary, followed by a section of mixed sample and ampholyte. During focusing, the NH 3 H 2 O section worked as catholyte. As focusing progressed, the NH 3 H 2 O section was titrated to lower pH by the acidic sheath electrolyte. Chemical mobilization started automatically once the ammonium hydroxide was consumed by the acidic sheath flow electrolyte, which then acted as the mobilization solution. In this report, the lengths of the NH 3 H 2 O section and sample were optimized. With a 1 m long capillary, a relative short plug of the NH 3 H 2 O section (3 cm) produced both fast migration and reasonable separation resolution. The simplified capillary isoelectric focusing mass spectrometry system produced base peak intensity relative standard deviation of 8.5% and migration time relative standard deviation ≤0.6% for myoglobin and cytochrome C in triplicate runs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“cIEF has been also reported for the analysis of other intact proteins94.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [94]
Citations
Cites
Adaptation of the equipment for high-performance electrophoresis to isoelectric focusing
Hjertén, S., & Zhu, M.-D. (1985) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)90512-0 · Cited by 437
Wojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234
Self-citationJensen, P. K., Paša-Tolić, L., Anderson, G. A., Horner, J. A., Lipton, M. S., Bruce, J. E., & Smith, R. D. (1999) · Analytical Chemistry · doi:10.1021/ac990196p · Cited by 231
Sun, L., Zhu, G., Zhang, Z., Mou, S., & Dovichi, N. J. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00100 · Cited by 216
Self-citationUltrasensitive and Fast Bottom‐up Analysis of Femtogram Amounts of Complex Proteome Digests
Sun, L., Zhu, G., Zhao, Y., Yan, X., Mou, S., & Dovichi, N. J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201308139 · Cited by 212
Self-citationHjertén, S., Liao, J.-L., & Yao, K. (1987) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)94519-4 · Cited by 184
Capillary electrophoresis and isoelectric focusing in peptide and protein analysis
Righetti, P. G., Sebastiano, R., & Citterio, A. (2013) · PROTEOMICS · doi:10.1002/pmic.201200378 · Cited by 166
Jensen, P. K., Paìa-Tolić, L., Hixson, K. K., Martinović, S., Lipton, M. S. W., Anderson, G., Tolić, N., Wong, K., & Smith, R. D. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:7<1363::aid-elps1363>3.0.co;2-u · Cited by 125
Capillary isoelectric focusing-electrospray mass spectrometry for protein analysis
Tang, Q. M., Harrata, A. K., & Lee, C. S. (1995) · Analytical Chemistry · doi:10.1021/ac00115a021 · Cited by 103
Zhu, G., Sun, L., & Dovic̀hi, N. J. (2015) · Talanta · doi:10.1016/j.talanta.2015.06.003 · Cited by 93
Self-citationMack, S., Cruzado‐Park, I. D., Chapman, J. D., Ratnayake, C. K., & Vigh, G. (2009) · Electrophoresis · doi:10.1002/elps.200800690 · Cited by 92
Zhu, G., Sun, L., Yan, X., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac5004486 · Cited by 78
Self-citationRamsay, L. M., Dickerson, J. A., Dada, O. O., & Dovic̀hi, N. J. (2009) · Analytical Chemistry · doi:10.1021/ac8025948 · Cited by 56
Self-citationFluorescence imaging detection for capillary isoelectric focusing
Wu, X., Wu, J., & Pawliszyn, J. B. (1995) · Electrophoresis · doi:10.1002/elps.11501601244 · Cited by 48
Macroporous polyacrylamide‐based monolithic column with immobilized pH gradient for protein analysis
Zhu, G., Yuan, H., Zhao, P., Zhang, L., Liang, Z., Zhang, W., & Zhang, Y. (2006) · Electrophoresis · doi:10.1002/elps.200600189 · Cited by 47
Self-citationOnline CIEF‐ESI‐MS in glycerol–water media with a view to hydrophobic protein applications
Mokaddem, M., Gareil, P., & Varenne, A. (2009) · Electrophoresis · doi:10.1002/elps.200900091 · Cited by 46
Zhu, G., Sun, L., Wojcik, R., Kernaghan, D., McGivney, J. B., & Dovic̀hi, N. J. (2012) · Talanta · doi:10.1016/j.talanta.2012.07.017 · Cited by 42
Self-citationAttomole protein analysis by CIEF with LIF detection
Ramsay, L. M., Dickerson, J. A., & Dovic̀hi, N. J. (2009) · Electrophoresis · doi:10.1002/elps.200800498 · Cited by 41
Self-citationMinárik, M., Groiss, F., Gaš, B., Blaas, D., & Kenndler, E. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(96)00083-0 · Cited by 38
Development and characterization of cIEF‐MALDI‐TOF MS for protein analysis
Silvertand, L. H. H., Toraño, J. S., de Jong, G. J., & van Bennekom, W. P. (2009) · Electrophoresis · doi:10.1002/elps.200800740 · Cited by 37
On-line amino acid-based capillary isoelectric focusing-ESI-MS/MS for protein digests analysis
Zhu, G., Sun, L., Yang, P., & Dovic̀hi, N. J. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.04.026 · Cited by 35
Self-citationZhu, G., Sun, L., Keithley, R. B., & Dovic̀hi, N. J. (2013) · Analytical Chemistry · doi:10.1021/ac4009868 · Cited by 31
Self-citationPreparation and application of monolithic columns with narrow immobilized pH gradients
Zhu, G., YANG, C., Zhang, L., LIANG, Z., Zhang, W., & ZHANG, Y. (2006) · Talanta · doi:10.1016/j.talanta.2005.12.037 · Cited by 28
Self-citationDada, O. O., Ramsay, L. M., Dickerson, J. A., Cermak, N., Jiang, R., Zhu, C., & Dovic̀hi, N. J. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3595-x · Cited by 26
Self-citationWeiss, N., Jarvis, J. W., Nelson, R., & Hayes, M. A. (2010) · Proteomics · doi:10.1002/pmic.201000310 · Cited by 15
Capillary isoelectric focusing with pH 9.7 cathode for the analysis of gastric biopsies
Ramsay, L. M., Cermak, N., Dada, O. O., & Dovic̀hi, N. J. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4926-2 · Cited by 12
Self-citation9 Capillary isoelectric focusing
Wehr, T. (2005) · Separation science and technology · doi:10.1016/s0149-6395(05)80012-1 · Cited by 6
Research works printed but not linked: 1
- 10.1002/(sici)1522-2683(20000401)21:7<1372::aid-elps1372>3.0.co;2-y · DOI · Paper page
Cited by
Stolz, A., Jooß, K., Höcker, O., Römer, J., Schlecht, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800331 · Cited by 214
Recent advances in protein analysis by capillary and microchip electrophoresis
Dawod, M., Arvin, N. E., & Kennedy, R. T. (2017) · The Analyst · doi:10.1039/c7an00198c · Cited by 145
Dai, J., Lamp, J., Xia, Q., & Zhang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04608 · Cited by 123
Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112
Recent advances (2019–2021) of capillary electrophoresis‐mass spectrometry for multilevel proteomics
Chen, D., McCool, E. N., Yang, Z., Shen, X., Lubeckyj, R. A., Xu, T., Wang, Q., & Sun, L. (2021) · Mass Spectrometry Reviews · doi:10.1002/mas.21714 · Cited by 106
Self-citation
Metadata
- Authors
- Zhu, G., Sun, L., & Dovichi, N. J.
- Affiliations
- University of Notre Dame (US)
- Department of Chemistry and Biochemistry University of Notre Dame Notre Dame IN USA
- ORCID
- Sun, Liangliang
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2016-12-30
- Volume
- 40
- Issue
- 4
- Pages
- 948-953
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2560120411
- Cited by
- 23
- References
- 27
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 2 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 2 · 2018: 5 · 2017: 3
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (R01GM096767)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- capillary isoelectric focusing, sequential injection, nanoelectrospray ionization, ion trap mass spectrometry, protein separation, myoglobin, cytochrome c, electrokinetic pumping
- MeSH terms
- Electrolytes, Hydrogen-Ion Concentration, Isoelectric Focusing, Myoglobin, Mass Spectrometry, Electrophoresis, Capillary, Cytochromes c
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.