CoChat

Pipette-tip solid-phase extraction based on deep eutectic solvent modified graphene for the determination of sulfamerazine in river water

Liu, Lingling, Tang, Weiyang, Tang, Baokun, Han, Dandan, Row, Kyung Ho, Zhu, Tao · 2017 · Journal of Separation Science

The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.

Abstract

A green and novel deep eutectic solvent modified graphene was prepared and used as a neutral adsorbent for the rapid determination of sulfamerazine in a river water sample by pipette‐tip solid‐phase extraction. Compared with conventional graphene, deep eutectic solvent modified graphene can change the surface of graphene with wrinkled structure and higher selective extraction ability. The properties of deep eutectic solvent modified graphene and graphene were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis. Static adsorption showed deep eutectic solvent modified graphene had a higher adsorption ability (18.62 mg/g) than graphene. Under the optimum conditions, factors such as kinds of washing solvents and elution solvents and volume of elution solvent were evaluated. The limits of detection and quantification were 0.01 and 0.03 μg/mL, respectively. The method recoveries of sulfamerazine were in the range of 91.01–96.82% with associated intraday relative standard deviations ranging from 1.63 to 3.46% and interday relative standard deviations ranging from 0.68 to 3.84%. Deep eutectic solvent modified graphene showed satisfactory results (recovery was 95.38%) and potential for rapid purification of sulfamerazine in river water sample in combination with the pipette‐tip solid‐phase extraction method.

Overview

Integrity signals

Registry

Crossref · 10.1002/jssc.201601436

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. 10.1016/j.talanta.2014.07.080 · DOI

Cited by

See all 64

Metadata

Authors
Liu, L., Tang, W., Tang, B., Han, D., Row, K. H., & Zhu, T.
Affiliations
  • Tianjin University of Technology (CN)
  • Hebei University (CN)
  • Inha University (KR)
Corresponding author
Zhu, Tao
Venue
Journal of Separation Science
Publisher
Wiley
Published
2017-04-05
Volume
40
Issue
9
Pages
1887-1895
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2591910560
Cited by
64
References
60
Citations by year
2025: 3 · 2024: 4 · 2023: 4 · 2022: 6 · 2021: 9 · 2020: 15 · 2019: 8 · 2018: 8 · 2017: 7
FWCI
7.27
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Separation Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Natural Science Foundation of Tianjin City (13JCYBJC42200)
  • Department of Education of Hebei Province (QN2016207)
  • Natural Science Foundation of Hebei Province (B2014201089)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
  • Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
Keywords
sulfamerazine, pipette-tip solid-phase extraction, deep eutectic solvents, modified graphene, river water, adsorbents, sulfonamide determination, preconcentration, adsorption capacity
MeSH terms
Graphite, Solvents, Sulfamerazine, Rivers, Solid Phase Extraction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.