Pipette-tip solid-phase extraction based on deep eutectic solvent modified graphene for the determination of sulfamerazine in river water
The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
A green and novel deep eutectic solvent modified graphene was prepared and used as a neutral adsorbent for the rapid determination of sulfamerazine in a river water sample by pipette‐tip solid‐phase extraction. Compared with conventional graphene, deep eutectic solvent modified graphene can change the surface of graphene with wrinkled structure and higher selective extraction ability. The properties of deep eutectic solvent modified graphene and graphene were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis. Static adsorption showed deep eutectic solvent modified graphene had a higher adsorption ability (18.62 mg/g) than graphene. Under the optimum conditions, factors such as kinds of washing solvents and elution solvents and volume of elution solvent were evaluated. The limits of detection and quantification were 0.01 and 0.03 μg/mL, respectively. The method recoveries of sulfamerazine were in the range of 91.01–96.82% with associated intraday relative standard deviations ranging from 1.63 to 3.46% and interday relative standard deviations ranging from 0.68 to 3.84%. Deep eutectic solvent modified graphene showed satisfactory results (recovery was 95.38%) and potential for rapid purification of sulfamerazine in river water sample in combination with the pipette‐tip solid‐phase extraction method.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The results demonstrated that the DES-graphene had the higher adsorption ability (18.62 mg/g) than graphene (17.36 mg/g), due to the DES-graphene had a larger winkle than graphene [123].”
From Hydrophobic deep eutectic solvents in microextraction techniques–A review (2020) · cites this paper as [123]
In the citing paper
“The extraction recovery by DES-G was 95.38%, whilst the G presented a 26.98% recovery rate [56].”
From Microextraction Techniques with Deep Eutectic Solvents (2020) · cites this paper as [56]
In the citing paper
“An antibacterial sulfonamide named sulfamerazine was the compound of interest to be extracted by Liu et al. [93], who applied pipette-tip solid-phase extraction (PT-SPE) with graphene modified by DES (ChCl-ethylene glycol) as the adsorbent.”
From Applications of Deep Eutectic Solvents in Sample Preparation and Extraction of Organic Molecules (2022) · cites this paper as [93]
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
Measurement of the Elastic Properties and Intrinsic Strength of Monolayer Graphene
Lee, C., Wei, X., Kysar, J. W., & Hone, J. (2008) · Science · doi:10.1126/science.1157996 · Cited by 20,847
Novoselov, K. S., Fal′ko, V. I., Colombo, L., Gellert, P. R., Schwab, M. G., & Kim, K. (2012) · Nature · doi:10.1038/nature11458 · Cited by 9,251
Abbott, A. P., Capper, G., Davies, D. L., Rasheed, R. K., & Tambyrajah, V. (2003) · Chemical Communications · doi:10.1039/b210714g · Cited by 5,738
Deep eutectic solvents: syntheses, properties and applications
Zhang, Q., De Oliveira Vigier, K., Royer, S., & Jérôme, F. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35178a · Cited by 4,899 · cited 1×
“The presence of antibiotic residues can produce several unfavorable effects like the development of microorganism resistance and, as a result, the possible harmful effects on the treatment of bacterial infections [46] and some sulfonamides antibiotics are even potentially carcinogenic [47–50].”
BackgroundChabot, V., Higgins, D., Yu, A., Xiao, X., Chen, Z., & Zhang, J. (2014) · Energy & Environmental Science · doi:10.1039/c3ee43385d · Cited by 1,119
Application of Hole Theory to Define Ionic Liquids by their Transport Properties
Abbott, A. P., Harris, R. C., & Ryder, K. S. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp0671998 · Cited by 556
D'Agostino, C., Harris, R. C., Abbott, A. P., Gladden, L. F., & Mantle, M. D. (2011) · Physical Chemistry Chemical Physics · doi:10.1039/c1cp22554e · Cited by 556
Design of improved deep eutectic solvents using hole theory
Abbott, A. P., Capper, G., & Gray, S. (2006) · ChemPhysChem · doi:10.1002/cphc.200500489 · Cited by 545 · cited 1×
“glycol (ChCl-EG) eutectic mixture exhibits relatively low freezing point, density and viscosity, allowing greater movement of the ionic species [45].”
BackgroundZhang, M., Liu, Y.-H., Shang, Z.-R., Hu, H.-C., & Zhang, Z.-H. (2017) · Catalysis Communications · doi:10.1016/j.catcom.2016.09.028 · Cited by 386
Research works printed but not linked: 1
- 10.1016/j.talanta.2014.07.080 · DOI
Cited by
Extraction techniques with deep eutectic solvents
Cunha, S. C., & Fernandes, J. O. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.05.001 · Cited by 760
Hydrophobic deep eutectic solvents in microextraction techniques–A review
Makoś, P., Słupek, E., & Gębicki, J. (2020) · Microchemical Journal · doi:10.1016/j.microc.2019.104384 · Cited by 469
“36mg/g), due to the DES-graphene had a larger winkle than graphene [123].”
BackgroundDeep eutectic solvents are not only effective extractants
Shishov, A., Pochivalov, A., Nugbienyo, L., Andruch, V., & Bulatov, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115956 · Cited by 278
Seidi, S., Tajik, M., Baharfar, M., & Rezazadeh, M. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.036 · Cited by 193
Soylak, M., & Koksal, M. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.04.006 · Cited by 158
Metadata
- Authors
- Liu, L., Tang, W., Tang, B., Han, D., Row, K. H., & Zhu, T.
- Affiliations
- Tianjin University of Technology (CN)
- Hebei University (CN)
- Inha University (KR)
- Corresponding author
- Zhu, Tao
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2017-04-05
- Volume
- 40
- Issue
- 9
- Pages
- 1887-1895
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2591910560
- Cited by
- 64
- References
- 60
- Citations by year
- 2025: 3 · 2024: 4 · 2023: 4 · 2022: 6 · 2021: 9 · 2020: 15 · 2019: 8 · 2018: 8 · 2017: 7
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Science Foundation of Tianjin City (13JCYBJC42200)
- Department of Education of Hebei Province (QN2016207)
- Natural Science Foundation of Hebei Province (B2014201089)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
- Keywords
- sulfamerazine, pipette-tip solid-phase extraction, deep eutectic solvents, modified graphene, river water, adsorbents, sulfonamide determination, preconcentration, adsorption capacity
- MeSH terms
- Graphite, Solvents, Sulfamerazine, Rivers, Solid Phase Extraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.