The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Ultraviolet laser‐induced fluorescence of colonic tissue: Basic biology and diagnostic potential
Abstract
Laser‐induced fluorescence (LIF) of colonic tissue was examined both in vitro and in vivo to assess the ability of the technique to distinguish neoplastic from hyperplastic and normal tissue and to relate the LIF spectra to specific constituents of the colon. Spectra from 86 normal colonic sites, 35 hyperplastic polyps, 49 adenomatous polyps, and 7 adenocarcinomas were recorded both in vivo and in vitro. With 337‐nm excitation, the fluorescence spectra all had peaks at 390 and 460 nm, believed to arise from collagen and NADH, and a minimum at 425 nm, consistent with absorption attributable to hemoglobin. The spectra of colonic tissue recorded both in vivo and in vitro are different, primarily in the NADH fluorescence component, which decays exponentially with time after resection. When normal colonic tissue is compared to hyperplastic or adenomatous polyps, the predominant changes in the fluorescence spectra are a decrease in collagen fluorescence and a slight increase in hemoglobin reabsorption. A multivariate linear regression (MVLR) analysis was used to distinguish neoplastic tissue from non‐neoplastic tissue with a sensitivity, specificity, predictive value positive, and predictive value negative toward neoplastic tissue of 80%, 92%, 82%, and 91%, respectively. When the MVLR technique was used to distinguish neoplastic polyps from non‐neoplastic polyps, values of 86%, 77%, 86%, and 77% respectively, were obtained. The data suggest that the LIF measurements sense changes in polyp morphology, rather than changes in fluorophores specific to polyps, and it is this change in morphology that leads indirectly to discrimination of polyps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chance, B., Cohen, P., Jobsis, F., & Schoener, B. (1962) · Science · doi:10.1126/science.137.3529.499 · Cited by 946
THE DETERMINATION OF COLLAGEN AND ELASTIN IN TISSUES
Neuman, R. E., & Logan, M. A. (1950) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)56248-7 · Cited by 817
Quantitation of hydroxypyridinium crosslinks in collagen by high-performance liquid chromatography
Eyre, D. R., Koob, T. J., & Van Ness, K. P. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90101-5 · Cited by 658
Fluorescence spectra from cancerous and normal human breast and lung tissues
Alfano, R., Tang, G., Pradhan, A., Lam, W., Choy, D., & Opher, E. (1987) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1987.1073234 · Cited by 347
THE FLUOROMETRIC MEASUREMENT OF THE NUCLEOTIDES OF RIBOFLAVIN AND THEIR CONCENTRATION IN TISSUES
Bessey, O. A., Lowry, O. H., & Love, R. H. (1949) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)56696-5 · Cited by 318
Laser-induced fluorescence spectroscopy of human colonic mucosa
Kapadia, C. R., Cutruzzola, F. W., O'Brien, K. M., Stetz, M. L., Enriquez, R., & Deckelbaum, L. I. (1990) · Gastroenterology · doi:10.1016/0016-5085(90)91242-x · Cited by 230
Fluorescence spectroscopy of turbid media: Autofluorescence of the human aorta
Keijzer, M., Richards-Kortum, R. R., Jacques, S. L., & Feld, M. S. (1989) · Applied Optics · doi:10.1364/ao.28.004286 · Cited by 222
Brain NADH redox state monitored in vivo by fiber optic surface fluorometry
Mayevsky, A. (1984) · Brain Research Reviews · doi:10.1016/0165-0173(84)90029-8 · Cited by 202
Characteristic autofluorescence for cancer diagnosis and its origin
Yuanlong, Y., Yanming, Y., Li, F., Yu-fen, L., & Paozhong, M. (1987) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900070617 · Cited by 141
Contribution of different enzymes to flavoprotein fluorescence of isolated rat liver mitochondria
Kunz, W. S., & Kunz, W. (1985) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(85)90064-9 · Cited by 128
ALUMINUM SULFONATED PHTHALOCYANINE DISTRIBUTION IN RODENT TUMORS OF THE COLON, BRAIN and PANCREAS
Tralau, C. J., Barr, H., Sandeman, D. R., Barton, T., Lewin, M. R., & Bown, S. G. (1987) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1987.tb04847.x · Cited by 106
Precancerous Lesions of the Gastrointestinal Tract
Ahlquist, D. A. (1984) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)61454-2 · Cited by 60
Physician accuracy in diagnosing colorectal polyps
Neale, A. V., Demers, R. Y., Budev, H., et al. (1987) · Diseases of the Colon & Rectum · doi:10.1007/bf02556164 · Cited by 57
O'Brien, K. M., Gmitro, A. F., Gindi, G. R., Stetz, M. L., Cutruzzola, F. W., Laifer, L. I., & Deckelbaum, L. I. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.18748 · Cited by 45
Autofluorescence of various rodent tissues and human skin tumour samples
Andersson, P. S., Kjellén, E., Montan, S., Svanberg, K., & Svanberg, S. R. (1987) · Lasers in Medical Science · doi:10.1007/bf02594130 · Cited by 45
Cited by
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
In Vivo Fluorescence Spectroscopy and Imaging for Oncological Applications
Wagnieres, G. A., Star, W. M., & Wilson, B. C. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02521.x · Cited by 942
Cell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887
Fluorescence Spectroscopy of Neoplastic and Non-Neoplastic Tissues
Ramanujam, N. (2000) · Neoplasia · doi:10.1038/sj.neo.7900077 · Cited by 654
Mourant, J. R., Fuselier, T., Boyer, J., Johnson, T. M., & Bigio, I. J. (1997) · Applied Optics · doi:10.1364/ao.36.000949 · Cited by 529
Metadata
- Authors
- Schomacker, K. T., Frisoli, J. K., Compton, C. C., Flotte, T. J., Richter, J. M., Nishioka, N. S., & Deutsch, T. F.
- Venue
- Lasers in Surgery and Medicine
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 12
- Issue
- 1
- Pages
- 63-78
- ISSN
- 0196-8092 (ISSN-L)
- 1096-9101
- OpenAlex
- W2040708168
- Cited by
- 416
- References
- 15
- FWCI
- 11.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.