Ionization techniques in capillary electrophoresis‐mass spectrometry: Principles, design, and application
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A major step forward in the development and application of capillary electrophoresis (CE) was its coupling to ESI‐MS, first reported in 1987. More than two decades later, ESI has remained the principal ionization technique in CE–MS, but a number of other ionization techniques have also been implemented. In this review the state‐of‐the‐art in the employment of soft ionization techniques for CE–MS is presented. First the fundamentals and general challenges of hyphenating conventional CE and microchip electrophoresis with MS are outlined. After elaborating on the characteristics and role of ESI, emphasis is put on alternative ionization techniques including sonic spray ionization (SSI), thermospray ionization (TSI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), matrix‐assisted laser desorption ionization (MALDI) and continuous‐flow fast atom bombardment (CF‐FAB). The principle of each ionization technique is outlined and the experimental set‐ups of the CE–MS couplings are described. The strengths and limitations of each ionization technique with respect to CE–MS are discussed and the applicability of the various systems is illustrated by a number of typical examples. © 2010 Wiley Periodicals, Inc., Mass Spec Rev 30:1096–1120, 2011
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Mischak, H., Coon, J. J., Novak, J., Weissinger, E. M., Schanstra, J. P., & Dominiczak, A. F. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20205 · Cited by 193
Cited by
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · Analytical Chemistry · doi:10.1021/ac303158f · Cited by 149
Self-citationCE‐MS for the analysis of intact proteins 2010–2012
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200439 · Cited by 96
Self-citationCE–MS for proteomics: Advances in interface development and application
Ramautar, R., Heemskerk, A. A. M., Hensbergen, P. J., Deelder, A. M., Busnel, J.-M., & Mayboroda, O. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.050 · Cited by 86
On‐line CE/ESI/MS interfacing: Recent developments and applications in proteomics
Krenkova, J., & Foret, F. (2012) · PROTEOMICS · doi:10.1002/pmic.201200140 · Cited by 44
Medina-Casanellas, S., Domínguez-Vega, E., Benavente, F., Sanz-Nebot, V., Somsen, G. W., & de Jong, G. J. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.12.080 · Cited by 36
Self-citation
Metadata
- Authors
- Hommerson, P., Khan, A. M., de Jong, G. J., & Somsen, G. W.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2011-04
- Volume
- 30
- Issue
- 6
- Pages
- 1096-1120
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2096951998
- Cited by
- 98
- References
- 3
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionization techniques in capillary electrophoresis‐mass spectrometry: Principles, design, and application. https://app.cochat.ai/papers/10.1002/mas.20313
- The paper
- Hommerson, P., Khan, A. M., de Jong, G. J., & Somsen, G. W. (2011). Ionization techniques in capillary electrophoresis‐mass spectrometry: Principles, design, and application. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.20313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.