Automatic assessment of levodopa‐induced dyskinesias in daily life by neural networks
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We developed an objective and automatic procedure to assess the severity of levodopa‐induced dyskinesia (LID) in patients with Parkinson's disease during daily life activities. Thirteen patients were continuously monitored in a home‐like situation for a period of approximately 2.5 hours. During this time period, the patients performed approximately 35 functional daily life activities. Behavior of the patients was measured using triaxial accelerometers, which were placed at six different positions on the body. A neural network was trained to assess the severity of LID using various variables of the accelerometer signals. Neural network scores were compared with the assessment by physicians, who evaluated the continuously videotaped behavior of the patients off‐line. The neural network correctly classified dyskinesia or the absence of dyskinesia in 15‐minute intervals in 93.7, 99.7, and 97.0% for the arm, trunk, and leg, respectively. In the few cases of misclassification, the rating by the neural network was in the class next to that indicated by the physicians using the AIMS score (scale 0–4). Analysis of the neural networks revealed several new variables, which are relevant for assessing the severity of LID. The results indicate that the neural network can accurately assess the severity of LID and could distinguish LID from voluntary movements in daily life situations. © 2002 Movement Disorder Society
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ECDEU Assessment Manual: (591322011-001)
Guy, W. (1976) · PsycEXTRA Dataset · doi:10.1037/e591322011-001 · Cited by 1,896
Cited by
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623
Halilaj, E., Rajagopal, A., Fiterau, M., Hicks, J. L., Hastie, T. J., & Delp, S. L. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.09.009 · Cited by 460
Bonato, P. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936554 · Cited by 423
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Quantitative wearable sensors for objective assessment of Parkinson's disease
Maetzler, W., Domingos, J., Srulijes, K., Ferreira, J. J., & Bloem, B. R. (2013) · Movement Disorders · doi:10.1002/mds.25628 · Cited by 374
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310
“[136], [137] and Hoff et al.”
Katzenschlager, R., Hughes, A., Evans, A., Manson, A. J., Hoffman, M., Swinn, L., Watt, H., Bhatia, K., Quinn, N., & Lees, A. J. (2005) · Movement Disorders · doi:10.1002/mds.20276 · Cited by 286
Kubota, K. J., Chen, J. A., & Little, M. A. (2016) · Movement Disorders · doi:10.1002/mds.26693 · Cited by 210
Ambulatory monitoring of physical activities in patients with Parkinson’s disease
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Burkhard, P. R., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.896591 · Cited by 217
“In the past few years, using accelerometers, [16] has proposed a system to determine periods of movements and rest, while [17] has described a method similar to [15] to classify different physical activity in PD patient, though they did not report an evaluation the performance of this.”
MethodWearable sensor-based objective assessment of motor symptoms in Parkinson’s disease
Ossig, C., Antonini, A., Buhmann, C., Classen, J., Csoti, I., Falkenburger, B., Schwarz, M., Winkler, J., & Storch, A. (2016) · Journal of Neural Transmission · doi:10.1007/s00702-015-1439-8 · Cited by 164
Body-worn sensors in Parkinson’s disease: evaluating their acceptability to patients
Fisher, J. M., Hammerla, N. Y., Rochester, L., Andras, P., & Walker, R. W. (2016) · Telemedicine and e-Health · doi:10.1089/tmj.2015.0026 · Cited by 81
Mera, T. O., Burack, M. A., & Giuffrida, J. P. (2013) · Journal of Parkinson’s Disease · doi:10.3233/jpd-120166 · Cited by 66
“Previous studies have shown that signal strength in the frequency range less than 3 Hz was effective for classifying dyskinesia [22, 26] while greater than 3 Hz was effective for classifying tremor [17].”
Dyskinesia detection and monitoring by a single sensor in patients with Parkinson's disease
Lopane, G., Mellone, S., Chiari, L., Cortelli, P., Calandra‐Buonaura, G., & Contin, M. (2015) · Movement Disorders · doi:10.1002/mds.26313 · Cited by 43
Continuous leg dyskinesia assessment in Parkinson's disease –clinical validity and ecological effect
Ramsperger, R., Meckler, S., Heger, T., van Uem, J., Hucker, S., Braatz, U., Graessner, H., Berg, D., Manoli, Y., Serrano, J. A., et al. (2016) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2016.02.007 · Cited by 41
Tsipouras, M. G., Tzallas, A. T., Karvounis, E. C., Tsalikakis, D. G., Cancela, J., Pastorino, M., Waldmeyer, M. T. A., Konitsiotis, S., & Fotiadis, D. I. (2014) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI) · doi:10.1109/bhi.2014.6864332 · Cited by 13
“The tremendous advances in microelectronics have led to the development of a new generation of movement sensors, which are smaller, cheaper, more robust, and more accurate than before [2-7].”
Background
Metadata
- Authors
- Keijsers, N. L. W., Horstink, M. W. I. M., & Gielen, S. C. A. M.
- Venue
- Movement Disorders
- Publisher
- Wiley
- Published
- 2002-10-10
- Volume
- 18
- Issue
- 1
- Pages
- 70-80
- ISSN
- 0885-3185 (ISSN-L)
- 1531-8257
- OpenAlex
- W2126401818
- Cited by
- 140
- References
- 1
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.