CoChat

High‐resolution tracking of motor disorders in Parkinson's disease during unconstrained activity

Open access
Roy, Serge H., Cole, Bryan T., Gilmore, L. Don, De Luca, Carlo J., Thomas, Cathi A., Saint‐Hilaire, Marie M., Nawab, S. Hamid · 2013 · Movement Disorders
Cited by 61

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Parkinson's disease (PD) can present with a variety of motor disorders that fluctuate throughout the day, making assessment a challenging task. Paper‐based measurement tools can be burdensome to the patient and clinician and lack the temporal resolution needed to accurately and objectively track changes in motor symptom severity throughout the day. Wearable sensor‐based systems that continuously monitor PD motor disorders may help to solve this problem, although critical shortcomings persist in identifying multiple disorders at high temporal resolution during unconstrained activity. The purpose of this study was to advance the current state of the art by (1) introducing hybrid sensor technology to concurrently acquire surface electromyographic (sEMG) and accelerometer data during unconstrained activity and (2) analyzing the data using dynamic neural network algorithms to capture the evolving temporal characteristics of the sensor data and improve motor disorder recognition of tremor and dyskinesia. Algorithms were trained (n = 11 patients) and tested (n = 8 patients; n = 4 controls) to recognize tremor and dyskinesia at 1‐second resolution based on sensor data features and expert annotation of video recording during 4‐hour monitoring periods of unconstrained daily activity. The algorithms were able to make accurate distinctions between tremor, dyskinesia, and normal movement despite the presence of diverse voluntary activity. Motor disorder severity classifications averaged 94.9% sensitivity and 97.1% specificity based on 1 sensor per symptomatic limb. These initial findings indicate that new sensor technology and software algorithms can be effective in enhancing wearable sensor‐based system performance for monitoring PD motor disorders during unconstrained activities. © 2013 Movement Disorder Society

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mds.25391

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 61

Metadata

Authors
Roy, S. H., Cole, B. T., Gilmore, L. D., De Luca, C. J., Thomas, C. A., Saint‐Hilaire, M. M., & Nawab, S. H.
Venue
Movement Disorders
Publisher
Wiley
Published
2013-03-20
Volume
28
Issue
8
Pages
1080-1087
ISSN
  • 0885-3185 (ISSN-L)
  • 1531-8257
OpenAlex
W2136259449
Cited by
61
References
6
FWCI
4.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.