Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 329

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Processed nerve allografts for peripheral nerve reconstruction: A multicenter study of utilization and outcomes in sensory, mixed, and motor nerve reconstructions

Brooks, Darrell N., Weber, Renata V., Chao, Jerome D., Rinker, Brian D., Zoldos, Jozef, Robichaux, Michael R., Ruggeri, Sebastian B., Anderson, Kurt A., Bonatz, Ekkehard E., Wisotsky, Scott M., Cho, Mickey S., Wilson, Christopher, Cooper, Ellis O., Ingari, John V., Safa, Bauback, Parrett, Brian M., Buncke, Gregory M.·2012·Microsurgery

Abstract

Purpose: As alternatives to autograft become more conventional, clinical outcomes data on their effectiveness in restoring meaningful function is essential. In this study we report on the outcomes from a multicenter study on processed nerve allografts (Avance® Nerve Graft, AxoGen, Inc). Patients and Methods: Twelve sites with 25 surgeons contributed data from 132 individual nerve injuries. Data was analyzed to determine the safety and efficacy of the nerve allograft. Sufficient data for efficacy analysis were reported in 76 injuries (49 sensory, 18 mixed, and 9 motor nerves). The mean age was 41 ± 17 (18–86) years. The mean graft length was 22 ± 11 (5–50) mm. Subgroup analysis was performed to determine the relationship to factors known to influence outcomes of nerve repair such as nerve type, gap length, patient age, time to repair, age of injury, and mechanism of injury. Results: Meaningful recovery was reported in 87% of the repairs reporting quantitative data. Subgroup analysis demonstrated consistency, showing no significant differences with regard to recovery outcomes between the groups ( P > 0.05 Fisher's Exact Test). No graft related adverse experiences were reported and a 5% revision rate was observed. Conclusion: Processed nerve allografts performed well and were found to be safe and effective in sensory, mixed and motor nerve defects between 5 and 50 mm. The outcomes for safety and meaningful recovery observed in this study compare favorably to those reported in the literature for nerve autograft and are higher than those reported for nerve conduits. © 2011 Wiley Periodicals, Inc. Microsurgery, 2012.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/micr.20975

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 329

Metadata

Authors
Brooks, D. N., Weber, R. V., Chao, J. D., Rinker, B. D., Zoldos, J., Robichaux, M. R., Ruggeri, S. B., Anderson, K. A., Bonatz, E. E., Wisotsky, S. M., Cho, M. S., Wilson, C., Cooper, E. O., Ingari, J. V., Safa, B., Parrett, B. M., & Buncke, G. M.
Venue
Microsurgery
Publisher
Wiley
Published
2011-11-28
Volume
32
Issue
1
Pages
1-14
ISSN
  • 0738-1085 (ISSN-L)
  • 1098-2752
OpenAlex
W2104439323
Cited by
329
References
28
FWCI
18.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Processed nerve allografts for peripheral nerve reconstruction: A multicenter study of utilization and outcomes in sensory, mixed, and motor nerve reconstructions. https://app.cochat.ai/papers/10.1002/micr.20975
The paper
Brooks, D. N., Weber, R. V., Chao, J. D., Rinker, B. D., Zoldos, J., Robichaux, M. R., Ruggeri, S. B., Anderson, K. A., Bonatz, E. E., Wisotsky, S. M., Cho, M. S., Wilson, C., Cooper, E. O., Ingari, J. V., Safa, B., Parrett, B. M., & Buncke, G. M. (2012). Processed nerve allografts for peripheral nerve reconstruction: A multicenter study of utilization and outcomes in sensory, mixed, and motor nerve reconstructions. Microsurgery. https://doi.org/10.1002/micr.20975

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.