Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 709

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

A deep convolutional neural network using directional wavelets for low‐dose X‐ray CT reconstruction

Open access
Kang, Eunhee, Min, Junhong, Ye, Jong Chul·2017·Medical Physics

Abstract

Purpose: Due to the potential risk of inducing cancer, radiation exposure by X‐ray CT devices should be reduced for routine patient scanning. However, in low‐dose X‐ray CT, severe artifacts typically occur due to photon starvation, beam hardening, and other causes, all of which decrease the reliability of the diagnosis. Thus, a high‐quality reconstruction method from low‐dose X‐ray CT data has become a major research topic in the CT community. Conventional model‐based de‐noising approaches are, however, computationally very expensive, and image‐domain de‐noising approaches cannot readily remove CT‐specific noise patterns. To tackle these problems, we want to develop a new low‐dose X‐ray CT algorithm based on a deep‐learning approach. Method: We propose an algorithm which uses a deep convolutional neural network (CNN) which is applied to the wavelet transform coefficients of low‐dose CT images. More specifically, using a directional wavelet transform to extract the directional component of artifacts and exploit the intra‐ and inter‐ band correlations, our deep network can effectively suppress CT‐specific noise. In addition, our CNN is designed with a residual learning architecture for faster network training and better performance. Results: Experimental results confirm that the proposed algorithm effectively removes complex noise patterns from CT images derived from a reduced X‐ray dose. In addition, we show that the wavelet‐domain CNN is efficient when used to remove noise from low‐dose CT compared to existing approaches. Our results were rigorously evaluated by several radiologists at the Mayo Clinic and won second place at the 2016 “Low‐Dose CT Grand Challenge.” Conclusions: To the best of our knowledge, this work is the first deep‐learning architecture for low‐dose CT reconstruction which has been rigorously evaluated and proven to be effective. In addition, the proposed algorithm, in contrast to existing model‐based iterative reconstruction (MBIR) methods, has considerable potential to benefit from large data sets. Therefore, we believe that the proposed algorithm opens a new direction in the area of low‐dose CT research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.12344

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 709

Metadata

Authors
Kang, E., Min, J., & Ye, J. C.
Venue
Medical Physics
Publisher
Wiley
Published
2017-10
Volume
44
Issue
10
Pages
e360-e375
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2542870090
Cited by
709
References
30
FWCI
28.53
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.