Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 229

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Cycle‐consistent adversarial denoising network for multiphase coronary CT angiography

Open access
Kang, Eunhee, Koo, Hyun Jung, Yang, Dong Hyun, Seo, Joon Bum, Ye, Jong Chul · 2019 · Medical Physics

Abstract

Purpose: In multiphase coronary CT angiography (CTA), a series of CT images are taken at different levels of radiation dose during the examination. Although this reduces the total radiation dose, the image quality during the low‐dose phases is significantly degraded. Recently, deep neural network approaches based on supervised learning technique have demonstrated impressive performance improvement over conventional model‐based iterative methods for low‐dose CT. However, matched low‐ and routine‐dose CT image pairs are difficult to obtain in multiphase CT. To address this problem, we aim at developing a new deep learning framework. Method: We propose an unsupervised learning technique that can remove the noise of the CT images in the low‐dose phases by learning from the CT images in the routine dose phases. Although a supervised learning approach is not applicable due to the differences in the underlying heart structure in two phases, the images are closely related in two phases, so we propose a cycle‐consistent adversarial denoising network to learn the mapping between the low‐ and high‐dose cardiac phases. Results: Experimental results showed that the proposed method effectively reduces the noise in the low‐dose CT image while preserving detailed texture and edge information. Moreover, thanks to the cyclic consistency and identity loss, the proposed network does not create any artificial features that are not present in the input images. Visual grading and quality evaluation also confirm that the proposed method provides significant improvement in diagnostic quality. Conclusions: The proposed network can learn the image distributions from the routine‐dose cardiac phases, which is a big advantage over the existing supervised learning networks that need exactly matched low‐ and routine‐dose CT images. Considering the effectiveness and practicability of the proposed method, we believe that the proposed can be applied for many other CT acquisition protocols.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.13284

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 229

Metadata

Authors
Kang, E., Koo, H. J., Yang, D. H., Seo, J. B., & Ye, J. C.
Venue
Medical Physics
Publisher
Wiley
Published
2018-12-26
Volume
46
Issue
2
Pages
550-562
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2887746098
Cited by
229
References
7
FWCI
12.09
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cycle‐consistent adversarial denoising network for multiphase coronary CT angiography. https://app.cochat.ai/papers/10.1002/mp.13284
The paper
Kang, E., Koo, H. J., Yang, D. H., Seo, J. B., & Ye, J. C. (2019). Cycle‐consistent adversarial denoising network for multiphase coronary CT angiography. Medical Physics. https://doi.org/10.1002/mp.13284

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.