The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Low‐dose CT image and projection dataset
Open accessAbstract
Purpose: To describe a large, publicly available dataset comprising computed tomography (CT) projection data from patient exams, both at routine clinical doses and simulated lower doses. Acquisition and Validation Methods: The library was developed under local ethics committee approval. Projection and image data from 299 clinically performed patient CT exams were archived for three types of clinical exams: noncontrast head CT scans acquired for acute cognitive or motor deficit, low‐dose noncontrast chest scans acquired to screen high‐risk patients for pulmonary nodules, and contrast‐enhanced CT scans of the abdomen acquired to look for metastatic liver lesions. Scans were performed on CT systems from two different CT manufacturers using routine clinical protocols. Projection data were validated by reconstructing the data using several different reconstruction algorithms and through use of the data in the 2016 Low Dose CT Grand Challenge. Reduced dose projection data were simulated for each scan using a validated noise‐insertion method. Radiologists marked location and diagnosis for detected pathologies. Reference truth was obtained from the patient medical record, either from histology or subsequent imaging. Data Format and Usage Notes: Projection datasets were converted into the previously developed DICOM‐CT‐PD format, which is an extended DICOM format created to store CT projections and acquisition geometry in a nonproprietary format. Image data are stored in the standard DICOM image format and clinical data in a spreadsheet. Materials are provided to help investigators use the DICOM‐CT‐PD files, including a dictionary file, data reader, and user manual. The library is publicly available from The Cancer Imaging Archive (https://doi.org/10.7937/9npb‐2637). Potential Applications: This CT data library will facilitate the development and validation of new CT reconstruction and/or denoising algorithms, including those associated with machine learning or artificial intelligence. The provided clinical information allows evaluation of task‐based diagnostic performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository
Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., et al. (2013) · Journal of Digital Imaging · doi:10.1007/s10278-013-9622-7 · Cited by 4,599
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
Chen, H., Zhang, Y., Kalra, M. K., Lin, F., Chen, Y., Liao, P., Zhou, J., & Wang, G. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2715284 · Cited by 1,866
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
A deep convolutional neural network using directional wavelets for low‐dose X‐ray CT reconstruction
Kang, E., Min, J., & Ye, J. C. (2017) · Medical Physics · doi:10.1002/mp.12344 · Cited by 709
Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT
Han, Y., & Ye, J. C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823768 · Cited by 588
Ordered subsets algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/11/311 · Cited by 556
A local update strategy for iterative reconstruction from projections
Sauer, K., & Bouman, C. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193196 · Cited by 494
A unified approach to statistical tomography using coordinate descent optimization
Bouman, C. A., & Sauer, K. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.491321 · Cited by 442
Shan, H., Zhang, Y., Yang, Q., Kruger, U., Kalra, M. K., Sun, L., Cong, W., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2832217 · Cited by 411
Li, M., Hsu, W., Xie, X., Cong, J., & Gao, W. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2968472 · Cited by 321
McCollough, C. H., Bartley, A. C., Carter, R. E., Chen, B., Drees, T. A., Edwards, P., Holmes, D. R., Huang, A. E., Khan, F., Leng, S., et al. (2017) · Medical Physics · doi:10.1002/mp.12345 · Cited by 308
Self-citationLi, Z., Yu, L., Trzasko, J. D., Lake, D. S., Blezek, D. J., Fletcher, J. G., McCollough, C. H., & Manduca, A. (2013) · Medical Physics · doi:10.1118/1.4851635 · Cited by 299
Self-citationYu, L., Shiung, M., Jondal, D., & McCollough, C. H. (2012) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e318258e891 · Cited by 169
Self-citationMa, Y., Wei, B., Feng, P., He, P., Guo, X., & Wang, G. (2020) · IEEE Access · doi:10.1109/access.2020.2986388 · Cited by 108
Investigation of Low-Dose CT Image Denoising Using Unpaired Deep Learning Methods
Li, Z., Zhou, S., Huang, J., Yu, L., & Jin, M. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.3007583 · Cited by 103
Self-citationKim, B., Han, M., Shim, H., & Baek, J. (2019) · Medical Physics · doi:10.1002/mp.13713 · Cited by 100
Fletcher, J. G., Yu, L., Li, Z., Manduca, A., Blezek, D. J., Hough, D. M., Venkatesh, S. K., Brickner, G. C., Cernigliaro, J. G., Hara, A. K., et al. (2015) · Radiology · doi:10.1148/radiol.2015141991 · Cited by 59
Self-citationFletcher, J. G., Fidler, J. L., Venkatesh, S. K., Hough, D. M., Takahashi, N., Yu, L., Johnson, M. P., Leng, S., Holmes, D. R., Carter, R. E., et al. (2018) · Radiology · doi:10.1148/radiol.2018180125 · Cited by 58
Self-citationEstimation of Observer Performance for Reduced Radiation Dose Levels in CT
Fletcher, J. G., Yu, L., Fidler, J. L., Levin, D. L., DeLone, D. R., Hough, D. M., Takahashi, N., Venkatesh, S. K., Sykes, A.-M. G., White, D. B., et al. (2017) · Academic Radiology · doi:10.1016/j.acra.2016.12.017 · Cited by 52
Self-citationSynthesizing images from multiple kernels using a deep convolutional neural network
Missert, A. D., Yu, L., Leng, S., et al. (2019) · Medical Physics · doi:10.1002/mp.13918 · Cited by 41
Self-citationGong, H., Yu, L., Leng, S., Dilger, S. K. N., Ren, L., Zhou, W., Fletcher, J. G., & McCollough, C. H. (2019) · Medical Physics · doi:10.1002/mp.13500 · Cited by 40
Self-citationLiver Extraction Using Residual Convolution Neural Networks From Low-Dose CT Images
Cheema, M. N., Nazir, A., Sheng, B., Li, P., Qin, J., & Feng, D. D. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2894123 · Cited by 37
Developments with maximum likelihood X-ray computed tomography
Browne, J. A., & Holmes, T. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.126909 · Cited by 36
Fletcher, J. G., Levin, D. L., Sykes, A.-M. G., et al. (2020) · Radiology · doi:10.1148/radiol.2020200969 · Cited by 23
Self-citationMissert, A., Leng, S., McCollough, C. H., et al. (2019) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2513240 · Cited by 6
Self-citation
Cited by
Advances in medical image analysis with vision Transformers: A comprehensive review
Azad, R., Kazerouni, A., Heidari, M., Aghdam, E. K., Molaei, A., Jia, Y., Jose, A., Roy, R., & Merhof, D. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103000 · Cited by 485
Metadata
- Authors
- Moen, T. R., Chen, B., Holmes, D. R., Duan, X., Yu, Z., Yu, L., Leng, S., Fletcher, J. G., & McCollough, C. H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2020-12-16
- Volume
- 48
- Issue
- 2
- Pages
- 902-911
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W3103645830
- Cited by
- 287
- References
- 26
- FWCI
- 10.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.