Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 270

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

On T2‐shortening by strongly magnetized spheres: A partial refocusing model

Open access
Gillis, Pierre, Moiny, Francis, Brooks, Rodney A.·2002·Magnetic Resonance in Medicine

Abstract

Computer simulations of water transverse relaxation induced by superparamagnetic particles are shown to disagree with the available theories, covering the slow diffusion domain. Understanding these new simulations, not in the slow diffusion domain, thus requires a new theoretical approach. A “partial refocusing model” is introduced for this purpose; it is based on a spatial division between an inner region where the gradients are too strong for the refocusing pulses to be efficient and an outer region where they are efficient. This model agrees with published simulations of relaxation induced by magnetic dipoles approximated as points. The validity domains of the various models are also compared. Magn Reson Med 47:257–263, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10059

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 270

Metadata

Authors
Gillis, P., Moiny, F., & Brooks, R. A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-01-23
Volume
47
Issue
2
Pages
257-263
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1995561619
Cited by
270
References
14
FWCI
4.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On T2‐shortening by strongly magnetized spheres: A partial refocusing model. https://app.cochat.ai/papers/10.1002/mrm.10059
The paper
Gillis, P., Moiny, F., & Brooks, R. A. (2002). On T2‐shortening by strongly magnetized spheres: A partial refocusing model. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10059

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.