CoChat

Detunable transverse electromagnetic (TEM) volume coil for high‐field NMR

Vaughan, J.T., Adriany, G., Garwood, M., Yacoub, E., Duong, T., DelaBarre, L., Andersen, P., Ugurbil, K. · 2002 · Magnetic Resonance in Medicine
Cited by 128

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Most high‐field MRI systems do not have the actively detuned body coils that are integral to clinical systems operating at 1.5T and lower field strengths. Therefore, many clinical applications requiring homogeneous volume excitation in combination with local surface coil reception are not easily implemented at high fields. To solve this problem for neuroimaging applications, actively detunable transverse electromagnetic (TEM) head coils were developed to be used with receive‐only surface coils for signal‐to‐noise ratio (SNR) gains and improved spatial coverage from homogeneously excited regions. These SNR and field of view (FOV) gains were achieved by application of a detunable TEM volume coil to human brain imaging at 4T. Magn Reson Med 47:990–1000, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10141

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 128

Metadata

Authors
Vaughan, J. T., Adriany, G., Garwood, M., Yacoub, E., Duong, T., DelaBarre, L., Andersen, P., & Ugurbil, K.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-04-23
Volume
47
Issue
5
Pages
990-1000
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2138274620
Cited by
128
References
1
FWCI
3.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.