The DOI matches its Crossref record.
Design of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imaging
Open accessAbstract
An 8‐channel receive‐only detector array was developed for SENSE MRI of human brain. The coil geometry was based on a gapped element design and used ultra‐high impedance preamplifiers for mutual decoupling of the elements. Computer simulations of the electric and magnetic fields showed that excellent signal‐to‐noise ratio (SNR) and SENSE performance could be achieved by placing the coil elements close to the head and maintaining a substantial gap between the elements. Measurements with a 1.5 T prototype coil showed a 2.7‐fold improvement of the SNR averaged over the brain compared to a conventional quadrature birdcage receive coil and an average geometrical noise amplification factor (g‐value) of 1.06 and 1.38 for rate‐2 and rate‐3 SENSE, respectively. Magn Reson Med 47:1218–1227, 2002. Published 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641
Self-citationMagnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
Self-citationTransmit and receive transmission line arrays for 7 Tesla parallel imaging
Adriany, G., Van de Moortele, P., Wiesinger, F., Moeller, S., Strupp, J. P., Andersen, P., Snyder, C., Zhang, X., Chen, W., Pruessmann, K. P., et al. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20321 · Cited by 421
Murphy, K., Bodurka, J., & Bandettini, P. A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.032 · Cited by 404
32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry
Wiggins, G. C., Triantafyllou, C., Potthast, A., Reykowski, A., Nittka, M., & Wald, L. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20925 · Cited by 375
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
Susceptibility contrast in high field MRI of human brain as a function of tissue iron content
Yao, B., Li, T.-Q., Gelderen, P. V., Shmueli, K., de Zwart, J. A., & Duyn, J. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.029 · Cited by 282
Self-citationElectrodynamics and ultimate SNR in parallel MR imaging
Wiesinger, F., Boesiger, P., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20183 · Cited by 282
Parallel imaging reconstruction using automatic regularization
Lin, F., Kwong, K. K., Belliveau, J. W., & Wald, L. L. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10718 · Cited by 266
The future of ultra-high field MRI and fMRI for study of the human brain
Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.065 · Cited by 261
Self-citationScalable multichannel MRI data acquisition system
Bodurka, J., Ledden, P. J., van Gelderen, P., Chu, R., de Zwart, J. A., Morris, D., & Duyn, J. H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10693 · Cited by 71
Self-citation
Metadata
- Authors
- de Zwart, J. A., Ledden, P. J., Kellman, P., van Gelderen, P., & Duyn, J. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-06
- Volume
- 47
- Issue
- 6
- Pages
- 1218-1227
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2103368607
- Cited by
- 192
- References
- 0
- FWCI
- 11.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.