Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 266

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Parallel imaging reconstruction using automatic regularization

Lin, Fa‐Hsuan, Kwong, Kenneth K., Belliveau, John W., Wald, Lawrence L.·2004·Magnetic Resonance in Medicine

Abstract

Increased spatiotemporal resolution in MRI can be achieved by the use of parallel acquisition strategies, which simultaneously sample reduced k‐space data using the information from multiple receivers to reconstruct full‐FOV images. The price for the increased spatiotemporal resolution in parallel MRI is the degradation of the signal‐to‐noise ratio (SNR) in the final reconstructed images. Part of the SNR reduction results when the spatially correlated nature of the information from the multiple receivers destabilizes the matrix inversion used in the reconstruction of the full‐FOV image. In this work, a reconstruction algorithm based on Tikhonov regularization is presented that reduces the SNR loss due to geometric correlations in the spatial information from the array coil elements. Reference scans are utilized as a priori information about the final reconstructed image to provide regularized estimates for the reconstruction using the L‐curve technique. This automatic regularization method reduces the average g‐factors in phantom images from a two‐channel array from 1.47 to 0.80 in twofold sensitivity encoding (SENSE) acceleration. In vivo anatomical images from an eight‐channel system show an averaged g‐factor reduction of 1.22 to 0.84 in 2.67‐fold acceleration. Magn Reson Med 51:559–567, 2004. © 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10718

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 266

Metadata

Authors
Lin, F., Kwong, K. K., Belliveau, J. W., & Wald, L. L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2004-02-25
Volume
51
Issue
3
Pages
559-567
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1999584433
Cited by
266
References
10
FWCI
16.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Parallel imaging reconstruction using automatic regularization. https://app.cochat.ai/papers/10.1002/mrm.10718
The paper
Lin, F., Kwong, K. K., Belliveau, J. W., & Wald, L. L. (2004). Parallel imaging reconstruction using automatic regularization. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10718

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.