The benefits of sensitivity‐encoded (SENSE) echo‐planar imaging (EPI) for functional MRI (fMRI) based on blood oxygen level‐dependent (BOLD) contrast were quantitatively investigated at 1.5 T. For experiments with 3.4 × 3.4 × 4.0 mm 3 resolution, SENSE allowed the single‐shot EPI image acquisition duration to be shortened from 24.1 to 12.4 ms, resulting in a reduced sensitivity to geometric distortions and T blurring. Finger‐tapping fMRI experiments, performed on eight normal volunteers, showed an overall 18% loss in t‐score in the activated area, which was substantially smaller than expected based on the image signal‐to‐noise ratio (SNR) and g‐factor, but similar to the loss predicted by a model that takes physiologic noise into account. Magn Reson Med 48:1011–1020, 2002. Published 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Horovitz, S. G., Fukunaga, M., de Zwart, J. A., van Gelderen, P., Fulton, S. C., Balkin, T. J., & Duyn, J. H. (2008) · Human Brain Mapping · doi:10.1002/hbm.20428 · Cited by 616
Self-citationImage reconstruction in SNR units: A general method for SNR measurement†
Kellman, P., & McVeigh, E. R. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20713 · Cited by 535
Self-citationB1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468
SMASH, SENSE, PILS, GRAPPA: How to Choose the Optimal Method
Blaimer, M., Breuer, F., Mueller, M., Heidemann, R. M., Griswold, M. A., & Jakob, P. M. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/01.rmr.0000136558.09801.dd · Cited by 449
Poser, B. A., Versluis, M. J., Hoogduin, J. M., & Norris, D. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20900 · Cited by 439
Laminar analysis of 7T BOLD using an imposed spatial activation pattern in human V1
Polimeni, J. R., Fischl, B., Greve, D. N., & Wald, L. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.005 · Cited by 431
Fukunaga, M., Horovitz, S. G., van Gelderen, P., de Zwart, J. A., Jansma, J. M., Ikonomidou, V. N., Chu, R., Deckers, R. H. R., Leopold, D. A., & Duyn, J. H. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.04.018 · Cited by 375
Self-citationOverview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Three dimensional echo-planar imaging at 7 Tesla
Poser, B. A., Koopmans, P. J., Witzel, T., Wald, L. L., & Barth, M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.108 · Cited by 284
Sensitivity of MRI resonance frequency to the orientation of brain tissue microstructure
Lee, J., Shmueli, K., Fukunaga, M., van Gelderen, P., Merkle, H., Silva, A. C., & Duyn, J. H. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910222107 · Cited by 263
Self-citationThe future of ultra-high field MRI and fMRI for study of the human brain
Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.065 · Cited by 261
Self-citationWiesinger, F., Van de Moortele, P., Adriany, G., De Zanche, N., Ugurbil, K., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20281 · Cited by 198
Mukai, I., Kim, D., Fukunaga, M., Japee, S., Marrett, S., & Ungerleider, L. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3002-07.2007 · Cited by 176
“We used a 3T GE scanner with a 16-channel head coil, and imaging parameters for the fMRI data were as follows: TE, 40 ms; TR, 2000 ms; voxel size, 1.5 1.5 2.5 mm; SENSE rate 2 (Pruessmann et al., 1999; de Zwart et al., 2002); and 22 oblique slices covering the occipital lobe.”
InfluentialImaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“When tSNR is dominated by these physiological processes, elevating the thermal noise by factor R does not have a commensurate impact on fCNR (de Zwart et al., 2002; de Zwart et al., 2006; Moeller et al., 2006); it can in fact be beneficial by allowing the use of single-shot versus segmented…”
BackgroundInfluentialFinding thalamic BOLD correlates to posterior alpha EEG
Liu, Z., de Zwart, J. A., Yao, B., van Gelderen, P., Kuo, L.-W., & Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.025 · Cited by 104
“…30 ms echo time (TE), 1.5 s repetition time (TR), 30 axial slices with 4 mm thickness and no inter-slice gap, 220×165 mm2 field of view (FOV) for 64×48 matrix and sensitivity encoding (SENSE) parallel imaging with an acceleration factor of two (rate-2) as described earlier (de Zwart et al., 2002).”
InfluentialSelf-citationScalable multichannel MRI data acquisition system
Bodurka, J., Ledden, P. J., van Gelderen, P., Chu, R., de Zwart, J. A., Morris, D., & Duyn, J. H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10693 · Cited by 71
“7, with coil sensitivity reference maps obtained from the array data itself, without body coil reference (9).”
BackgroundSelf-citationPerthen, J. E., Bydder, M., Restom, K., & Liu, T. T. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.10.008 · Cited by 32
“Very similar trends were observed for the data after removal of stimulus-related components, with the exception of the perfusion R=2 values with noise reduction, which were slightly higher than the theoretical prediction (Pb.05) when the stimulus-related components were removed.”
Result
Metadata
- Authors
- de Zwart, J. A., van Gelderen, P., Kellman, P., & Duyn, J. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-12
- Volume
- 48
- Issue
- 6
- Pages
- 1011-1020
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2124410669
- Cited by
- 145
- References
- 0
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.