The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Metabolic profiles of human brain tumors using quantitative in vivo 1H magnetic resonance spectroscopy
Abstract
Proton spectroscopy can noninvasively provide useful information on brain tumor type and grade. Short‐ (30 ms) and long‐ (136 ms) echo time (TE) 1 H spectra were acquired from normal white matter (NWM), meningiomas, grade II astrocytomas, anaplastic astrocytomas, glioblastomas, and metastases. Very low myo‐Inositol ([mI]) and creatine ([Cr]) were characteristic of meningiomas, and high [mI] characteristic of grade II astrocytomas. Tumor choline ([Cho]) was greater than NWM and increased with grade for grade II and anaplastic astrocytomas, but was highly variable for glioblastomas. Higher [Cho] and [Cr] correlated with low lipid and lactate (P < 0.05), indicating a dilution of metabolite concentrations due to necrosis in high‐grade tumors. Metabolite peak area ratios showed no correlation with lipids and mI/Cho (at TE = 30 ms), and Cr/Cho (at TE = 136 ms) best correlated with tumor grade. The quantified lipid, macromolecule, and lactate levels increased with grade of tumor, consistent with progression from hypoxia to necrosis. Quantification of lipids and macromolecules at short TE provided a good marker for tumor grade, and a scatter plot of the sum of alanine, lactate, and δ1.3 lipid signals vs. mI/Cho provided a simple way to separate most tumors by type and grade. Magn Reson Med 49:223–232, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Improved Method for Accurate and Efficient Quantification of MRS Data with Use of Prior Knowledge
Vanhamme, L., van den Boogaart, A., & Van Huffel, S. (1997) · Journal of Magnetic Resonance · doi:10.1006/jmre.1997.1244 · Cited by 1,627
Grading of astrocytomas: A simple and reproducible method
Daumas-Duport, C., Scheithauer, B., O'Fallon, J., & Kelly, P. (1988) · Cancer · doi:10.1002/1097-0142(19881115)62:10<2152::aid-cncr2820621015>3.0.co;2-t · Cited by 891
In vivo proton spectroscopy in presence of eddy currents
Klose, U. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140104 · Cited by 580
Preul, M. C., Caramanos, Z., Collins, D. L., Villemure, J.-G., Leblanc, R., Olivier, A., Pokrupa, R., & Arnold, D. L. (1996) · Nature Medicine · doi:10.1038/nm0396-323 · Cited by 523
Analysis of macromolecule resonances in 1H NMR spectra of human brain
Behar, K. L., Rothman, D. L., Spencer, D. D., & Petroff, O. A. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320304 · Cited by 467
SVD-based quantification of magnetic resonance signals
Pijnappel, W. W. F., van den Boogaart, A., de Beer, R., & van Ormondt, D. (1992) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(92)90241-x · Cited by 350
Correlation of myo-inositol levels and grading of cerebral astrocytomas.
Castillo, M., Smith, J. K., & Kwock, L. (2000) · PubMed Central · Cited by 349
Proton MR Spectroscopy of Intracranial Tumours: In Vivo and In Vitro Studies
Gill, S. S., Thomas, D. G. T., Bruggen, N. V., Gadian, D. G., Peden, C. J., Bell, J. D., Cox, I. J., Menon, D. K., Iles, R. A., Bryant, D. J., et al. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199007000-00001 · Cited by 307
Complications of CT-guided stereotactic biopsy of intra-axial brain lesions
Bernstein, M., & Parrent, A. G. (1994) · Journal of Neurosurgery · doi:10.3171/jns.1994.81.2.0165 · Cited by 304
Hakumäki, J. M., Poptani, H., Sandmair, A.-M., Ylä-Herttuala, S., & Kauppinen, R. A. (1999) · Nature Medicine · doi:10.1038/15279 · Cited by 258
Automated single‐voxel proton MRS: Technical development and multisite verification
Webb, P. G., Sailasuta, N., Kohler, S. J., Raidy, T., Moats, R. A., & Hurd, R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310404 · Cited by 246
Cheng, L. L., Chang, I. W., Louis, D. N., & González, R. G. (1998) · PubMed · Cited by 208
Kinoshita, Y., & Yokota, A. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199701)10:1<2::aid-nbm442>3.0.co;2-n · Cited by 192
Just, M., & Thelen, M. (1988) · Radiology · doi:10.1148/radiology.169.3.3187000 · Cited by 176
Barba, I., Cabañas, M. E., & Arús, C. (1999) · PubMed · Cited by 169
Remy, C. C., Fouilhé, N., Barba, I., Lai, E. S., Lahrech, H., Cucurella, M., Izquierdo, M., Moreno, A., Ziegler, A., MASSARELLI, R., et al. (1997) · PubMed · Cited by 140
Towards a method for automated classification of1H MRS spectra from brain tumours
Tate, A. R., Griffiths, J. R., Martínez-Pérez, I., Moreno, À., Barba, I., Cabañas, M. E., Watson, D. M., Alonso, J., Bartumeus, F., Isamat, F., et al. (1998) · NMR in Biomedicine · Cited by 126
Self-citationCheng, L. L., Anthony, D. C., Comite, A. R., Black, P. M., Tzika, A. A., & González, R. G. (2000) · Neuro-Oncology · doi:10.1093/neuonc/2.2.87 · Cited by 112
Usenius, J., Vainio, P. A., Hernesniemi, J. A., & Kauppinen, R. A. (1994) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1994.63041538.x · Cited by 103
Detection of elevated glutathione in meningiomas by quantitative in vivo1H MRS
Opstad, K. S., Provencher, S. W., Bell, B. A., Griffiths, J. R., & Howe, F. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10416 · Cited by 99
Self-citationBarton, S. J., Howe, F. A., Tomlins, A. M., Cudlip, S., Nicholson, J. K., Bell, B. A., & Griffiths, J. R. (1999) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf02590529 · Cited by 86
Self-citationHagberg, G. E., Burlina, A. P., Mader, I., et al. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340216 · Cited by 69
Quantitative proton magnetic resonance spectroscopy of focal brain lesions
Wilken, B., Dechent, P., Herms, J. W., Maxton, C., Markakis, E., Hanefeld, F. A., & Frahm, J. (2000) · Pediatric Neurology · doi:10.1016/s0887-8994(00)00141-7 · Cited by 61
Manton, D. J., Lowry, M., Blackband, S. J., & Horsman, A. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080305 · Cited by 60
Pediatric Low-grade Gliomas: Prognosis with Proton Magneti Resonance Spectroscopic Imaging
Lazareff, J. A., Bockhorst, K. H. J., Curran, J. G., Olmstead, C. E., & Alger, J. (1998) · Neurosurgery · doi:10.1097/00006123-199810000-00053 · Cited by 50
Cited by
Dunn, W. B., Broadhurst, D. I., Atherton, H. J., Goodacre, R., & Griffin, J. L. (2011) · Chem. Soc. Rev. · doi:10.1039/b906712b · Cited by 860
Clinical Applications of Metabolomics in Oncology: A Review
Spratlin, J. L., Serkova, N. J., & Eckhardt, S. G. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-1059 · Cited by 753
Metabolic profiles of cancer cells
Griffin, J. L., & Shockcor, J. P. (2004) · Nature Reviews Cancer · doi:10.1038/nrc1390 · Cited by 725
Amide proton transfer (APT) contrast for imaging of brain tumors
Zhou, J., Lal, B., Wilson, D. A., Laterra, J., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10651 · Cited by 660
Clinical Proton MR Spectroscopy in Central Nervous System Disorders
Öz, G., Alger, J. R., Barker, P. B., Bartha, R., Bizzi, A., Boesch, C., Bolan, P. J., Brindle, K. M., Cudalbu, C., Dinçer, A., et al. (2014) · Radiology · doi:10.1148/radiol.13130531 · Cited by 660
Self-citation
Metadata
- Authors
- Howe, F. A., Barton, S. J., Cudlip, S. A., Stubbs, M., Saunders, D. E., Murphy, M., Wilkins, P., Opstad, K. S., Doyle, V. L., McLean, M. A., Bell, B. A., & Griffiths, J. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-01-22
- Volume
- 49
- Issue
- 2
- Pages
- 223-232
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1991413275
- Cited by
- 539
- References
- 25
- FWCI
- 18.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.