CoChat

In vivo measurement of brain metabolites using two‐dimensional double‐quantum MR spectroscopy—exploration of GABA levels in a ketogenic diet

Open access
Wang, Zhiyue J., Bergqvist, Christina, Hunter, Jill V., Jin, Dongzhu, Wang, Dah‐Jyuu, Wehrli, Suzanne, Zimmerman, Robert A. · 2003 · Magnetic Resonance in Medicine
Cited by 84

The DOI matches its Crossref record.

Abstract

A localized proton 2D double‐quantum (DQ) spin‐echo spectroscopy technique was implemented on 1.5 T clinical MRI scanners for the detection of γ‐aminobutyrate (GABA) in the brain. The 2D approach facilitates separation of peaks overlapping with GABA in 1D DQ‐filtered (DQF) spectra. This technique was applied to four normal adult volunteers and four children with intractable epilepsy. The coefficient of variation of the level of GABA and overlapping macromolecules at F2 = 3.0 ppm and F1 = 4.8 ppm was 0.08 in normal subjects. Three patients received 2D MRS scans before and after initiation of the ketogenic diet (KD): one patient showed a trend of decreasing GABA throughout the study, and two patients showed low initial GABA levels that increased over time. In addition to major metabolites and GABA, low‐level metabolites (valine, leucine, and glutathione) were also identified in the 2D spectra. Magn Reson Med 49:615–619, 2003. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10429

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Wang, Z. J., Bergqvist, C., Hunter, J. V., Jin, D., Wang, D., Wehrli, S., & Zimmerman, R. A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-03-18
Volume
49
Issue
4
Pages
615-619
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2025721608
Cited by
84
References
0
FWCI
3.10
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.