CoChat

Combination of transfection agents and magnetic resonance contrast agents for cellular imaging: Relationship between relaxivities, electrostatic forces, and chemical composition

Open access
Kalish, H., Arbab, A.S., Miller, B.R., Lewis, B.K., Zywicke, H.A., Bulte, J.W.M., Bryant, L.H., Frank, J.A. · 2003 · Magnetic Resonance in Medicine
Cited by 128

The DOI matches its Crossref record.

Abstract

The purpose of this study was to investigate the changes in electrostatic and magnetic resonance (MR) properties observed when MR contrast agents (CAs) (Feridex®, MION‐46L, or G5‐dendrimer‐DOTA‐Gd) are combined with transfection agents (TAs) under various conditions for use as a CA‐TA complex basis for cellular labeling and MRI. CAs were incubated with various classes of TAs for 0–48 hr in solutions of varying concentrations and pH values. NMR relaxation rates (1/T1, 1/T2), MRI and zeta potential (ZP) of CA‐TA solutions were measured. TAs decreased the 1/T1 and 1/T2 of G5‐DOTA‐Gd, Feridex®, and MION‐46L by 0–95%. Altering the pH of G5‐DOTA‐Gd‐TA decreased the T1‐weighted signal intensity (SI) on MRI from 0 to 78%. Measured ZP values for G5‐DOTA‐Gd, Feridex®, and MION‐46L were −51, −41, and −2.0 mV, respectively. The TA LV had a negative ZP, while the other TAs had ZPs ranging from +20 to +65 mV. The alteration of the ZP and NMR relaxivities of the MR CAs, Feridex®, MION‐46L, and G5‐DOTA‐Gd by TAs has been demonstrated. These results enhance our understanding of the relationship between electrostatic and MR properties. Magn Reson Med 50:275–282, 2003. Published 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10556

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kalish, H., Arbab, A. S., Miller, B. R., Lewis, B. K., Zywicke, H. A., Bulte, J. W. M., Bryant, L. H., & Frank, J. A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-07-17
Volume
50
Issue
2
Pages
275-282
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2013478089
Cited by
128
References
0
FWCI
8.05
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.