The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Intracytoplasmic tagging of cells with ferumoxides and transfection agent for cellular magnetic resonance imaging after cell transplantation: methods and techniques
Abstract
BACKGROUND: Superparamagnetic iron oxides (SPIO) are being used to label cells for in vivo monitoring by magnetic resonance imaging (MRI). The purpose of this study is to present protocols using SPIO and a polycationic transfection agent for magnetic labeling of cells as a basis for cellular MRI. METHODS: Various concentrations of ferumoxides (FE)-poly-l-lysine (PLL) complexes were used to magnetically label cells. Iron incorporation into cells along with cell viability and short- and long-term toxicity were evaluated. RESULTS: Rapidly growing cell suspension and adherent cells were effectively labeled by means of endocytosis into endosomes at low concentrations of FE (25 microg/mL media) and PLL (0.75 microg/mL media). Hematopoietic stem cells and lymphocytes required higher concentrations of PLL (1.5 microg/mL) in serum-free media during initial FE-PLL complex formation before labeling the cells in culture. Total iron concentration in cells depended on the cell type, concentration of FE-PLL complexes in media, cellular density, and incubation time. Iron concentrations after overnight incubation with given FE at 25 microg/mL media resulted in, for example, T cells being labeled with 1 to 3 pg/cell of intracytoplasmic endosomal iron and 15 to 20 pg/cell of intracytoplasmic iron in mesenchymal stem cells compared with 0.01 to 0.1 pg/cell for unlabeled cells. Protocols developed for this study demonstrated no adverse effect on the cell viability, functional capacity, or toxicity. CONCLUSION: This technique can be used to label cells for in vivo MRI tracking of stem cells and lymphocytes. FE at a concentration of 25 to 50 microg/mL with a ratio of SPIO to PLL of 1:0.03 to 1:0.06 would be sufficient to label cells for cellular MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilineage potential of adult human mesenchymal stem cells
Pittenger, M. F., Mackay, A. M., Beck, S. C., Jaiswal, R. K., Douglas, R., Mosca, J. D., Moorman, M. A., Simonetti, D. W., Craig, S., & Marshak, D. R. (1999) · Science · doi:10.1126/science.284.5411.143 · Cited by 21,052
Lewin, M., Carlesso, N., Tung, C.-H., Tang, X.-W., Cory, D., Scadden, D. T., & Weissleder, R. (2000) · Nature Biotechnology · doi:10.1038/74464 · Cited by 1,716
Derivation of pluripotent stem cells from cultured human primordial germ cells
Shamblott, M. J., Axelman, J., Wang, S., Bugg, E. M., Littlefield, J. W., Donovan, P. J., Blumenthal, P. D., Huggins, G. R., & Gearhart, J. D. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.23.13726 · Cited by 1,420
Deans, R. J., & Moseley, A. B. (2000) · Experimental Hematology · doi:10.1016/s0301-472x(00)00482-3 · Cited by 1,412
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B., Bacon, B., Compton, C., White, D., Jacobs, P., & Lewis, J. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells
Bulte, J. W. M., Douglas, T., Witwer, B., Zhang, S.-C., Strable, E., Lewis, B. K., Zywicke, H., Miller, B., van Gelderen, P., Moskowitz, B. M., et al. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1141 · Cited by 1,027
Self-citationHigh-Efficiency Intracellular Magnetic Labeling with Novel Superparamagnetic-Tat Peptide Conjugates
Josephson, L., Tung, C.-H., Moore, A., & Weissleder, R. (1999) · Bioconjugate Chemistry · doi:10.1021/bc980125h · Cited by 882
In vivo magnetic resonance imaging of transgene expression
Weissleder, R., Moore, A., Mahmood, U., Bhorade, R., Benveniste, H., Chiocca, E. A., & Basilion, J. P. (2000) · Nature Medicine · doi:10.1038/73219 · Cited by 776
Hoehn, M., Küstermann, E., Blunk, J., Wiedermann, D., Trapp, T., Wecker, S., Föcking, M., Arnold, H., Hescheler, J., Fleischmann, B. K., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.242435499 · Cited by 707
Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M. (2003) · Radiology · doi:10.1148/radiol.2281020638 · Cited by 643
Self-citation
Cited by
Interaction of Nanoparticles with Cells
Mailänder, V., & Landfester, K. (2009) · Biomacromolecules · doi:10.1021/bm900266r · Cited by 576
Efficient magnetic cell labeling with protamine sulfate complexed to ferumoxides for cellular MRI
Arbab, A. S., Yocum, G. T., Kalish, H., Jordan, E. K., Anderson, S. A., Khakoo, A. Y., Read, E. J., & Frank, J. A. (2004) · Blood · doi:10.1182/blood-2004-02-0655 · Cited by 529
Self-citationLiu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Nanotechnology, nanotoxicology, and neuroscience
Suh, W. H., Suslick, K. S., Stucky, G. D., & Suh, Y.-H. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2008.09.009 · Cited by 406
Arbab, A. S., Wilson, L. B., Ashari, P., Jordan, E. K., Lewis, B. K., & Frank, J. A. (2005) · NMR in Biomedicine · doi:10.1002/nbm.970 · Cited by 347
Self-citation
Metadata
- Authors
- Arbab, A. S., Bashaw, L. A., Miller, B. R., Jordan, E. K., Bulte, J. W. M., & Frank, J. A.
- Venue
- Transplantation
- Published
- 2003-10-15
- Volume
- 76
- Issue
- 7
- Pages
- 1123-1130
- ISSN
- 0041-1337 (ISSN-L)
- OpenAlex
- W2031783970
- Cited by
- 253
- References
- 25
- FWCI
- 13.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracytoplasmic tagging of cells with ferumoxides and transfection agent for cellular magnetic resonance imaging after cell transplantation: methods and techniques. https://app.cochat.ai/papers/10.1097/01.tp.0000089237.39220.83
- The paper
- Arbab, A. S., Bashaw, L. A., Miller, B. R., Jordan, E. K., Bulte, J. W. M., & Frank, J. A. (2003). Intracytoplasmic tagging of cells with ferumoxides and transfection agent for cellular magnetic resonance imaging after cell transplantation: methods and techniques. Transplantation. https://doi.org/10.1097/01.tp.0000089237.39220.83
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.