The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Parallel imaging reconstruction using automatic regularization
Abstract
Increased spatiotemporal resolution in MRI can be achieved by the use of parallel acquisition strategies, which simultaneously sample reduced k‐space data using the information from multiple receivers to reconstruct full‐FOV images. The price for the increased spatiotemporal resolution in parallel MRI is the degradation of the signal‐to‐noise ratio (SNR) in the final reconstructed images. Part of the SNR reduction results when the spatially correlated nature of the information from the multiple receivers destabilizes the matrix inversion used in the reconstruction of the full‐FOV image. In this work, a reconstruction algorithm based on Tikhonov regularization is presented that reduces the SNR loss due to geometric correlations in the spatial information from the array coil elements. Reference scans are utilized as a priori information about the final reconstructed image to provide regularized estimates for the reconstruction using the L‐curve technique. This automatic regularization method reduces the average g‐factors in phantom images from a two‐channel array from 1.47 to 0.80 in twofold sensitivity encoding (SENSE) acceleration. In vivo anatomical images from an eight‐channel system show an averaged g‐factor reduction of 1.22 to 0.84 in 2.67‐fold acceleration. Magn Reson Med 51:559–567, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized Cross-Validation as a Method for Choosing a Good Ridge Parameter
Golub, G. H., Heath, M., & Wahba, G. (1979) · Technometrics · doi:10.1080/00401706.1979.10489751 · Cited by 3,934
Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion
Hansen, P. C. (1998) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719697 · Cited by 2,909
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion
Hansen, P. C. (1987) · Medical Entomology and Zoology · Cited by 2,122
Practical Approximate Solutions to Linear Operator Equations When the Data are Noisy
Wahba, G. (1977) · SIAM Journal on Numerical Analysis · doi:10.1137/0714044 · Cited by 798
Design of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imaging
de Zwart, J. A., Ledden, P. J., Kellman, P., van Gelderen, P., & Duyn, J. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10169 · Cited by 192
Specific coil design for SENSE: A six-element cardiac array
Weiger, M., Pruessmann, K. P., Leussler, C. G., R�schmann, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · Cited by 183
Reduction of Gradient Acoustic Noise in MRI Using SENSE-EPI
de Zwart, J. A., Vangelderen, P., Kellman, P., & Duyn, J. H. (2002) · NeuroImage · doi:10.1006/nimg.2002.1119 · Cited by 65
Cited by
Deshmane, A., Gulani, V., Griswold, M. A., & Seiberlich, N. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23639 · Cited by 606
Whole brain susceptibility mapping using compressed sensing
Wu, B., Li, W., Guidon, A., & Liu, C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23000 · Cited by 417
Compressed sensing MRI: a review of the clinical literature
Jaspan, O. N., Fleysher, R., & Lipton, M. L. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20150487 · Cited by 393
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
Linear inverse problems in imaging
Ribes, A., & Schmitt, F. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.923099 · Cited by 154
Metadata
- Authors
- Lin, F., Kwong, K. K., Belliveau, J. W., & Wald, L. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-02-25
- Volume
- 51
- Issue
- 3
- Pages
- 559-567
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1999584433
- Cited by
- 266
- References
- 10
- FWCI
- 16.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.