Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 228

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

On T2‐shortening by weakly magnetized particles: The chemical exchange model†

Brooks, Rodney A., Moiny, Francis, Gillis, Pierre·2001·Magnetic Resonance in Medicine

Abstract

Chemical exchange (CE) theory is compared with two theories of T2‐shortening caused by microscopic magnetic centers: inner‐ and outer‐sphere relaxation theory (long‐echo limit) and mean gradient diffusion theory (short‐echo limit). The CE equation is shown to be identical to these theories in the respective limits and appropriate parameter relationships are derived for spherical particles. The theories are then compared with computer simulations of spherical particles and with a recent general theory, with good agreement in the asymptotic regions. The CE model also reproduces the essential relaxation characteristics in the intermediate range. Finally, good agreement of a CE model with simulations for magnetized cylinders is also demonstrated. The discussion is limited to weakly magnetized particles such that the maximum phase shift during an echo interval is less than one radian, permitting the use of the Luz‐Meiboom CE equation. Magn Reson Med 45:1014–1020, 2001. Published 2001 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1135

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 228

Metadata

Authors
Brooks, R. A., Moiny, F., & Gillis, P.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2001-05-23
Volume
45
Issue
6
Pages
1014-1020
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2113601288
Cited by
228
References
1
FWCI
4.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.