The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
MR fluoroscopy: Technical feasibility
Abstract
A method of magnetic resonance image acquisition and reconstruction is described in which high imaging rates and fast reconstruction times are allowed. The acquisition is a modification of the basic FLASH sequence but with a restricted number N of phase encodings. The encodings are applied sequentially, periodically, and continuously. Images are formed by sliding a window of width N encodings along the acquired data and reconstructing an image for each position of the window. In general the acquisition time per image exceeds the time between successive images, and the method thus has a temporal lag. Experimental studies were performed with a dynamic phantom using 48 phase encodings and a TR of 20 ms, for an image acquisition time of about 1 s. The image display rate in the reconstructed sequence was 12.5 images/s, and the image sequence portrayed the motion of the phantom. Additional studies were done with 24 encodings. It is shown how the sliding window technique lends itself to high‐speed reconstruction, with each newly acquired echo used to quickly update the image on display. The combination of the acquisition technique described and a hardware implementation of the reconstruction algorithm can result in realtime MR image acquisition and reconstruction. © 1988 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Application of Fourier Transform Spectroscopy to Magnetic Resonance
Ernst, R. R., & Anderson, W. A. (1966) · Review of Scientific Instruments · doi:10.1063/1.1719961 · Cited by 1,683
Rapid NMR imaging of dynamic processes using the FLASII technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030217 · Cited by 381
Halving MR imaging time by conjugation: demonstration at 3.5 kG.
Feinberg, D. A., Hale, J. D., Watts, J. C., Kaufman, L., & Mark, A. (1986) · Radiology · doi:10.1148/radiology.161.2.3763926 · Cited by 259
Biological and medical imaging by NMR
Mansfield, P., & Pykett, I. L. (1978) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(78)90159-2 · Cited by 186
Real‐time movie imaging from a single cardiac cycle by NMR
Chapman, B. L. W., Turner, R., Ordidge, R. J., Doyle, M., Cawley, M. G., Coxon, R., Glover, P. M., & Mansfield, P. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050305 · Cited by 168
REAL-TIME CARDIAC IMAGING OF ADULTS AT VIDEO FRAME RATES BY MAGNETIC RESONANCE IMAGING
Doyle, M., Chapman, B., Turner, R., Ordidge, R. J., Cawley, M., Coxon, R., Glover, P., Coupland, R. E., Morris, G. K., & Worthington, B. S. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90185-6 · Cited by 144
Cine MR determination of left ventricular ejection fraction
Utz, J. A., Herfkens, R. J., Heinsimer, J. A., Bashore, T. M., Califf, R. M., Glover, G. H., Pelc, N. J., & Shimakawa, A. S. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.5.839 · Cited by 117
Self-citationTransectional echo planar imaging of the heart in cyanotic congenital heart disease
Chrispin, A. R., Small, P., Rutter, N., COUPLAND, R. E., Doyle, M., Chapman, B. L. W., Coxon, R., Guilfoyle, D. N., Cawley, M. G., & Mansfield, P. (1986) · Pediatric Radiology · doi:10.1007/bf02386865 · Cited by 27
Cited by
A deep cascade of convolutional neural networks for dynamic MR image reconstruction
Schlemper, J., Caballero, J., Hajnal, J. V., Price, A. N., & Rueckert, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2760978 · Cited by 1,338
Time‐resolved contrast‐enhanced 3D MR angiography
Korosec, F. R., Frayne, R., Grist, T. M., & Mistretta, C. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360304 · Cited by 877
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
Real‐time MRI at a resolution of 20 ms
Uecker, M., Zhang, S., Voit, D., Karaus, A., Merboldt, K., & Frahm, J. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1585 · Cited by 434
Madore, B., Glover, G. H., & Pelc, N. J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s · Cited by 433
Metadata
- Authors
- Riederer, S. J., Tasciyan, T., Farzaneh, F., Lee, J. N., Wright, R. C., & Herfkens, R. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1988-09
- Volume
- 8
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2038630137
- Cited by
- 370
- References
- 8
- FWCI
- 5.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.