The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Localized high‐resolution proton NMR spectroscopy using stimulated echoes: Initial applications to human brain in vivo
Open accessAbstract
Water‐suppressed localized proton NMR spectroscopy using stimulated echoes has been successfully applied to detect metabolites in the human brain in vivo. The STEAM spectroscopy sequence allows single‐step localization by exciting three intersecting slices. Water suppression is achieved by preceding chemical‐shift‐selective (CHESS) rf pulses. High‐resolution (0.05 ppm) proton NMR spectra of healthy volunteers have been obtained on a conventional 1.5‐T whole‐body MRI system (Siemens Magnetom). Volumes‐of‐interest (VOI) of 64 ml(4 × 4 × 4 cm 3) were localized in the occipital area of the brain and spectra were recorded within measuring times ranging from I s (single scan) to about 10 min. The experimental procedure is described in detail. Resonance assignments include acetate, N‐acetyl aspartate, γ‐amino butyrate, glutamine, glutamate, aspartate, creatine and phosphocreatine, choline‐containing compounds, taurine, and inositols. Cerebral lactate was found to be at a maximum concentration of 0.5 m M when assuming N‐acetyl aspartate in white matter to be 6 m M. © 1989 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inositol Trisphosphate, a Novel Second Messenger in Cellular Signal Transduction
Berridge, M. J., & Irvine, R. F. (1984) · Nature · doi:10.1038/312315a0 · Cited by 6,086
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
Self-citation1H NMR chemical shift selective (CHESS) imaging
Haase, A., Frahm, J., Hanicke, W., & Matthaei, D. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/008 · Cited by 1,062
Self-citationMapping of metabolites in whole animals by 31P NMR using surface coils
Ackerman, J. J. H., Grove, T. H., Wong, G. G., Gadian, D. G., & Radda, G. K. (1980) · Nature · doi:10.1038/283167a0 · Cited by 1,005
Localized proton spectroscopy using stimulated echoes
Frahm, J., Merboldt, K.-D., & Hänicke, W. (1987) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(87)90154-5 · Cited by 826
Self-citationFLASH imaging. Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hanicke, W., & Merboldt, K.-D. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90433-6 · Cited by 826
Self-citationImage-selected in Vivo spectroscopy (ISIS). A new technique for spatially selective nmr spectroscopy
Ordidge, R. J., Connelly, A., & Lohman, J. A. B. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90031-4 · Cited by 811
Rapid NMR imaging of dynamic processes using the FLASII technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030217 · Cited by 381
Self-citationThe Use of NMR Spectroscopy for the Understanding of Disease
Radda, G. K. (1986) · Science · doi:10.1126/science.3726553 · Cited by 249
Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation
Frahm, J., Merboldt, K., & Hänicke, W. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060412 · Cited by 228
Self-citationMotion Artifact Suppression Technique (MAST) for MR Imaging
Pattany, P. M., Phillips, J. J., Chiu, L. C., Lipcamon, J. D., Duerk, J. L., McNally, J. M., & Mohapatra, S. N. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198705000-00001 · Cited by 217
Frahm, J., Merboldt, K. D., Hänicke, W., & Haase, A. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90033-2 · Cited by 192
Self-citationSpatially localized 1H NMR spectra of metabolites in the human brain.
Hanstock, C. C., Rothman, D. L., Prichard, J. W., Jue, T., & Shulman, R. G. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.6.1821 · Cited by 189
Biochemistry and the central nervous system
(1986) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(86)90232-6 · Cited by 115
Gordon, R. E., Hanley, P. E., & Shaw, D. (1982) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/0079-6565(82)80007-1 · Cited by 110
MR image-guided P-31 MR spectroscopy in the evaluation of brain tumor treatment.
Segebarth, C. M., Balériaux, D. F., Arnold, D. L., Luyten, P. R., & den Hollander, J. A. (1987) · Radiology · doi:10.1148/radiology.165.1.3628774 · Cited by 108
1H NMR detection of cerebral myo‐inositol
Cerdán, S., Parrilla, R., Santoro, J., et al. (1985) · FEBS Letters · doi:10.1016/0014-5793(85)81235-7 · Cited by 104
Gordon, R. E. (1982) · Bioscience Reports · doi:10.1007/bf01114832 · Cited by 73
Neurometabolic effects of an inborn error of amino acid metabolism demonstrated in vivo by 1H NMR
Gadian, D. G., Proctor, E., Williams, S. R., Cady, E. B., & Gardiner, R. M. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030123 · Cited by 64
The effect of magnetic susceptibility variations in NMR imaging and nmr spectroscopy in vivo
Cox, I. J., Bydder, G. M., Gadian, D. G., YOUNG, I. R., Proctor, E., Williams, S. R., & Hart, I. R. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90373-2 · Cited by 41
Frahm, J. (1987) · Die Naturwissenschaften · doi:10.1007/bf00446096 · Cited by 17
Self-citationMotion rephasing in gradient-localized spectroscopy
Gyngell, M. L., Frahm, J., Merboldt, K. D., Hänicke, W., & Bruhn, H. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90020-0 · Cited by 11
Self-citation
Cited by
Krssak, M., Falk Petersen, K., Dresner, A., DiPietro, L., Vogel, S. M., Rothman, D. L., Shulman, G. I., & Roden, M. (1999) · Diabetologia · doi:10.1007/s001250051123 · Cited by 1,264
Simultaneousin vivo spectral editing and water suppression
Mescher, M., Merkle, H., Kirsch, J., Garwood, M., & Gruetter, R. (1998) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199810)11:6<266::aid-nbm530>3.0.co;2-j · Cited by 1,015
Proton nuclear magnetic resonance spectroscopy unambiguously identifies different neural cell types
Urenjak, J., Williams, Sr., Gadian, D., & Noble, M. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-03-00981.1993 · Cited by 995
The role of skeletal muscle insulin resistance in the pathogenesis of the metabolic syndrome
Petersen, K. F., Dufour, S., Savage, D. B., Bilz, S., Solomon, G., Yonemitsu, S., Cline, G. W., Befroy, D., Zemany, L., Kahn, B. B., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705408104 · Cited by 759
Schwenzer, N. F., Springer, F., Schraml, C., Stefan, N., Machann, J., & Schick, F. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.05.023 · Cited by 749
Metadata
- Authors
- Frahm, J., Bruhn, H., Gyngell, M. L., Merboldt, K. D., Hänicke, W., & Sauter, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1989-01
- Volume
- 9
- Issue
- 1
- Pages
- 79-93
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2104150998
- Cited by
- 709
- References
- 23
- FWCI
- 44.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.