The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Perfusion imaging
Abstract
Measurement of tissue perfusion is important for the functional assessment of organs in vivo. Here we report the use of 1 H NMR imaging to generate perfusion maps in the rat brain at 4.7 T. Blood water flowing to the brain is saturated in the neck region with a sliceselective saturation imaging sequence, creating an endogenous tracer in the form of proximally saturated spins. Because proton T 1 times are relatively long, particularly at high field strengths, saturated spins exchange with bulk water in the brain and a steady state is created where the regional concentration of saturated spins is determined by the regional blood flow and regional T 1. Distal saturation applied equidistantly outside the brain serves as a control for effects of the saturation pulses. Average cerebral blood flow in normocapnic rat brain under halothane anesthesia was determined to be 105 ± 16 cc. 100 g−1. min−1 (mean ± SEM, n = 3), in good agreement with values reported in the literature, and was sensitive to increases in arterial p CO 2. This technique allows regional perfusion maps to be measured noninvasively, with the resolution of 1 H MRI, and should be readily applicable to human studies. © 1992 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
What is the Correct Value for the Brain-Blood Partition Coefficient for Water?
Herscovitch, P., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.9 · Cited by 705
Functional cerebral imaging by susceptibility‐contrast NMR
Belliveau, J. W., Rosen, B. R., Kantor, H. L., Rzedzian, R. R., Kennedy, D. N., McKinstry, R. C., Vevea, J. M., Cohen, M. S., Pykett, I. L., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140311 · Cited by 570
Brooker, H. R. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90089-6 · Cited by 455
Projection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
Baron, J. C., Frackowiak, R. S. J., Herholz, K., Jones, T., Lammertsma, A. A., Mazoyer, B., & Wienhard, K. (1989) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1989.105 · Cited by 168
Blood Flow and Metabolic Rate for Oxygen in the Cerebral Cortex of the Rat
Eklöf, B., Lassen, N. A., Nilsson, L., Norberg, K. A., & Siesjö, B. K. (1973) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1973.tb05489.x · Cited by 129
Cerebral Blood Flow: Physiologic and clinical Aspects
Gewertz, B. L. (1988) · Annals of Vascular Surgery · doi:10.1016/s0890-5096(06)60788-7 · Cited by 110
Measurement of regional cerebral blood flow in cat brain using intracarotid 2H2O and 2H NMR imaging
Detre, J. A., Subramanian, V. H., Mitchell, M. D., Smith, D. S., Kobayashi, A., Zaman, A., & Leigh, J. S. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140223 · Cited by 65
Self-citationJones, S. C., Greenberg, J. H., & Reivich, M. (1982) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198202000-00020 · Cited by 62
The Effect of Halothane Anaesthesia upon Cerebral Oxygen Consumption in the Rat
Harp, J. R., Nilsson, L., & Siesjö, B. K. (1976) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1976.tb05013.x · Cited by 27
Cited by
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationNeurocognitive consequences of sleep deprivation
Goel, N., Rao, H., Durmer, J., & Dinges, D. (2009) · Seminars in Neurology · doi:10.1055/s-0029-1237117 · Cited by 2,154
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
Metadata
- Authors
- Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 23
- Issue
- 1
- Pages
- 37-45
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W4233867216
- Cited by
- 1,571
- References
- 11
- FWCI
- 19.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.