T1 and t2 of ferritin at different field strengths: effect on mri
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Nuclear magnetic relaxation times T1 and T2 were measured in ferritin solutions at field strengths from 0.04 to 1.5 T.T1 was relatively constant, but 1/T2 increased linearly with field strength, in agreement with earlier MRI observations in the monkey brain. This finding supports the theory that ferritin is responsible for T2 shortening in brain nuclei containing iron. The linear dependence of 1/T2 on magnetic field is unique and not explained by present theories of the magnetic properties of ferritin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Cited by
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Vymazal, J., Righini, A., Brooks, R. A., Canesi, M., Mariani, C., Leonardi, M., & Pezzoli, G. (1999) · Radiology · doi:10.1148/radiology.211.2.r99ma53489 · Cited by 342
Self-citationHigh‐field magnetic resonance imaging of brain iron: birth of a biomarker?
Schenck, J. F., & Zimmerman, E. A. (2004) · NMR in Biomedicine · doi:10.1002/nbm.922 · Cited by 337
Earley, C. J., Connor, J., Garcia-Borreguero, D., Jenner, P., Winkelman, J., Zee, P. C., & Allen, R. (2014) · Sleep Medicine · doi:10.1016/j.sleep.2014.05.009 · Cited by 336
Magnetic resonance relaxation properties of superparamagnetic particles
Gossuin, Y., Gillis, P., Hocq, A., Vuong, Q. L., & Roch, A. (2009) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.36 · Cited by 319
Developing MR reporter genes: promises and pitfalls
Gilad, A. A., Winnard, P. T., van Zijl, P. C. M., & Bulte, J. W. M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1134 · Cited by 189
“However, the T2 relaxation enhancement of normal, native ferritin increases linearly with field strength, (133,136) making it a more efficient T2 contrast agent at higher fields.”
BackgroundMagnetic Resonance Imaging of Iron Deposition in Neurological Disorders
Brass, S. D., Chen, N.-K., Mulkern, R. V., & Bakshi, R. (2006) · Topics in Magnetic Resonance Imaging · doi:10.1097/01.rmr.0000245459.82782.e4 · Cited by 189
“0-T and greater) are especially sensitive to iron (see below).(1,35,36,43) However, a potential trade-off related to 3.”
BackgroundThe relation between brain iron and NMR relaxation times: An in vitro study
Vymazal, J., Brooks, R. A., Baumgarner, C., Tran, V., Katz, D., Bulte, J. W. M., Bauminger, E. R., & Chiro, G. D. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350108 · Cited by 172
Self-citationMagnetic resonance imaging of brain iron
Schenck, J. F. (2003) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(02)00431-8 · Cited by 116
MRI assessment of iron deposition in multiple sclerosis
Ropele, S., de Graaf, W., Khalil, M., Wattjes, M. P., Langkammer, C., Rocca, M. A., Rovira, A., Palace, J., Barkhof, F., Filippi, M., et al. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22590 · Cited by 103
“Additionally, the sensitivity of this approach varies between brain regions (25) and does not significantly increase with higher field strengths (15).”
Background
Metadata
- Authors
- Vymazal, J., Brooks, R. A., Zak, O., Mcrill, C., Shen, C., & Chiro, G. D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-10
- Volume
- 27
- Issue
- 2
- Pages
- 368-374
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2010417083
- Cited by
- 109
- References
- 1
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.