Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Developing MR reporter genes: promises and pitfalls

Open access
Gilad, Assaf A., Winnard, Paul T., van Zijl, Peter C. M., Bulte, Jeff W. M. · 2007 · NMR in Biomedicine

Abstract

MR reporter genes have the potential to monitor transgene expression non‐invasively in real time at high resolution. These genes can be applied to interrogate the efficacy of gene therapy, to assess cellular differentiation, cell trafficking, and specific metabolic activity, and also assess changes in the microenvironment. Efforts toward the development of MR reporter genes have been made for at least a decade, but, despite these efforts, the field is still in its early developmental stage. This reflects the fact that there are potential pitfalls, caused by the low sensitivity of detection, the need for substrates with their associated undesirable pharmacokinetics, and/or the difficult and, in some cases, delayed interpretation of signal changes. Nevertheless, significant progress has been made during the last few years. Whereas enzyme‐based reporters were initially applied to NMR spectroscopic monitoring of changes in phosphor and fluorine metabolism, MRI‐based approaches are now emerging that rely on: (1) enzyme‐based cleavage of functional groups that block water (proton) exchange or protein binding of MR contrast agents; (2) expression of surface receptors that enable binding of specific MR contrast agents; (3) expression of para‐ and anti‐ferromagnetic (metallo)proteins involved with iron metabolism, such as tyrosinase, transferrin receptor, and ferritin. After an introduction to the basic principles of designing promoters, expression vectors, and cloning of transgenes, a fresh look is provided on the use of reporter genes for optical (including bioluminescent) and nuclear imaging, with which MR reporter genes compete. Although progress in the use of MR reporter genes has been slow, newer strategies that use metalloproteins or alternative contrast mechanisms, with no need for substrates, promise rapid growth potential for this field. Copyright © 2007 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.1134

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 189

Metadata

Authors
Gilad, A. A., Winnard, P. T., van Zijl, P. C. M., & Bulte, J. W. M.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2007-04-24
Volume
20
Issue
3
Pages
275-290
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W2056380295
Cited by
189
References
6
FWCI
15.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Developing MR reporter genes: promises and pitfalls. https://app.cochat.ai/papers/10.1002/nbm.1134
The paper
Gilad, A. A., Winnard, P. T., van Zijl, P. C. M., & Bulte, J. W. M. (2007). Developing MR reporter genes: promises and pitfalls. NMR in Biomedicine. https://doi.org/10.1002/nbm.1134

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.