The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
4 Tesla gradient recalled echo characteristics of photic stimulation‐induced signal changes in the human primary visual cortex
Abstract
Multi‐echo measurements of photic stimulation‐induced signal changes in human visual cortex were made at 4 Tesla in order to quantify the nature of the signal change and its vascular origin, and to determine the optimum echo time for detection of the changes. Utilizing high resolution images, two distinct regions (ascribed to be microvasculature and visible venous vessels) were identified as giving rise to the signal increase. The fractional signal changes in gray matter areas depended linearly on echo time (TE) in the range of 10 to 60 ms and extrapolated to virtually zero for TE = 0, indicating that in‐flow effects secondary to stimulation‐induced blood flow increases were negligible in our functional imaging studies; instead, signal change due to photic stimulation originated from the increase in the apparent transverse relaxation rate, 1/T2*. This decrease in (1/T2*, brought about by the alterations in hemodynamic parameters, was 1.3 ± 0.4 s−1 for gray matter and 3.0 ± 0.7 s−1 (averaged over 10 individuals) for venous vessels visible in the images. The optimum choice of echo time was found to be TE ≥ T2*.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Self-citationDynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Solving Least Squares Problems.
Ling, R. F., Lawson, C. L., & Hanson, R. J. (1977) · Journal of the American Statistical Association · doi:10.2307/2286501 · Cited by 2,723
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Self-citationFox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Self-citationBrain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
Self-citationFunctional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H., Kwong, K. K., Le Bihan, D., Zeffiro, T., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 457
Functional MRI of human brain activation at high spatial resolution
Frahm, J., Merboldt, K., & Hänicke, W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290126 · Cited by 350
Ogawa, S., Lee, T. M., & Barrere, B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290208 · Cited by 281
Self-citationMenon, R. S., & Allen, P. S. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910200205 · Cited by 136
Self-citationFunctional brain imaging at 1.5 T using conventional gradient echo MR imaging techniques
Constable, R. T., McCarthy, G., Allison, T., Anderson, A. W., & Gore, J. C. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90463-n · Cited by 121
Motor cortex stimulation measured by magnetic resonance imaging on a standard 1.5 T clinical scanner
Schad, L. R., Trost, U., Knopp, M. V., Müller, E., & Lorenz, W. J. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90464-o · Cited by 50
Cited by
A developmental functional MRI study of prefrontal activation during performance of a go-no-go task
Casey, B. J., Trainor, R. J., Orendi, J. L., Schubert, A. B., Nystrom, L. E., Giedd, J. N., Castellanos, F. X., Haxby, J. V., Noll, D. C., Cohen, J. D., et al. (1997) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1997.9.6.835 · Cited by 1,106
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
The neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationA Model for the Coupling between Cerebral Blood Flow and Oxygen Metabolism during Neural Stimulation
Buxton, R. B., & Frank, L. R. (1997) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199701000-00009 · Cited by 807
Metadata
- Authors
- Menon, R. S., Ogawa, S., Tank, D. W., & Uǧurbil, K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-09
- Volume
- 30
- Issue
- 3
- Pages
- 380-386
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2014875176
- Cited by
- 413
- References
- 14
- FWCI
- 20.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.