The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at l.5T preliminary results
Abstract
We have measured the T2* signal response associated with cortical activation due to finger motion at 1.5 Tesla. Both thin slice 2D and 3D images show signal intensity changes which vary from 2% to 32% depending on volunteer, echo time, slice thickness, and in‐plane resolution. The largest signal change occurred for the thinnest slices and highest resolution (2 mm 3). This is consistent with reducing partial volume effects and a simple difference in phase between the intravascular signal and surrounding parenchyma. No inflow enhancement was seen on the 2D or 3D scans, confirming the nature of the signal difference for this approach was due to local field in‐homogeneity effects. Using 3D imaging, multiple effects can be seen simultaneously. With a 3D MRA method, it was possible to locate the vessel that was the source of the T2* behavior; it was in each case a vein on the surface of the cortical parenchyma.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Indeed, activity in the AIC is a common feature in studies of cognitive control and inhibitory processing [7, 46–50] and reward sensitivity [8, 9].”
From The role of the anterior insula in adolescent decision making (2014) · cites this paper as [50]
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,269
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H. H., Kwong, K. K., Bihan, D. L., Zeffiro, T. A., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 454
Dynamic MR imaging of human brain oxygenation during rest and photic stimulation
Frahm, J., Bruhn, H., Merboldt, K., & Hänicke, W. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020505 · Cited by 385
Functional imaging of human motor cortex at high magnetic field
Kim, S., Ashe, J., Georgopoulos, A. P., Merkle, H., Ellermann, J., Menon, R. S., Ogawa, S., & Uǧurbil, K. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.1.297 · Cited by 375
Functional MRI of human brain activation at high spatial resolution
Frahm, J., Merboldt, K., & Hänicke, W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290126 · Cited by 350
Experimental Researches in Electricity
Faraday, M. (2012) · Cambridge University Press eBooks · doi:10.1017/cbo9781139383158 · Cited by 291
Basic physics of MR contrast agents and maximization of image contrast
Hendrick, R. E., & Haacke, E. M. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030126 · Cited by 149
Self-citationReduction of T2* dephasing in gradient field-echo imaging.
Haacke, E. M., Tkach, J. A., & Parrish, T. B. (1989) · Radiology · doi:10.1148/radiology.170.2.2911669 · Cited by 134
Self-citation
Research works printed but not linked: 3
- Selwood P. W., 1943, Magnetochemistry, 163
- Kwong K. K., 1992, J. Magn. Reson. Imaging, 2, 76
- Bandettini P. A., 1992, J. Magn. Reson. Imaging, 2, 76
Cited by
Sorted by citations
Localization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. A. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,840
Retinotopic organization in human visual cortex and the spatial precision of functional MRI
Engel, S. A. (1997) · Cerebral Cortex · doi:10.1093/cercor/7.2.181 · Cited by 1,606
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,201
Self-citationThe human amygdala and the emotional evaluation of sensory stimuli
Zald, D. H. (2003) · Brain Research Reviews · doi:10.1016/s0165-0173(02)00248-5 · Cited by 1,062
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Metadata
- Authors
- Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R.
- Affiliations
- Case Western Reserve University (US)
- Corresponding author
- Haacke, E. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-09
- Volume
- 30
- Issue
- 3
- Pages
- 387-392
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2013713875
- Cited by
- 390
- References
- 12
- Citations by year
- 2025: 2 · 2024: 6 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 2 · 2019: 2 · 2018: 2 · 2017: 7 · 2016: 4 · 2015: 8 · 2014: 8 · 2013: 3 · 2012: 13
- FWCI
- 27.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Magnetic Resonance in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute on Aging (NIA AG08012)
- National Institute of Mental Health (NIMH 41684)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- vascular architecture, motor cortex activation, finger movement, 1.5 Tesla, partial volume effect, cerebral veins, cerebral blood volume, three-dimensional MR angiography
- MeSH terms
- Brain, Cerebrovascular Circulation, Fingers, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Motor Cortex, Movement, Signal Processing, Computer-Assisted, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review