Water diffusion and acute stroke
Abstract
The occlusion of the middle cerebral artery was used as an experimental acute stroke model in 30 cats. The diffusion of water was followed by diffusion‐sensitized MRI between 1 and 15 h after induction of stroke. It is demonstrated that images representing the trace of the diffusion tensor provide a much more accurate delineation of affected area than images representing the diffusion in one direction only. The reason is that the strong contrast caused by the anisotropy and orientation of myelin fibers is completely removed in the trace of the diffusion tensor. The trace images show a small contrast between white and gray matter. The diffusion coefficient of white matter is decreased in acute stroke to approximately the same extent as gray matter. It is further shown that the average lifetime of water in extra and intracellular space is shorter than 20 ms both for healthy and ischemic tissue indicating that myelin fibers are permeable to water. The anisotropy contrast did not change before or after induction of stroke, nor after sacrifice. Together, these observations are consistent with the view that the changes in water diffusion during acute stroke are directly related to cytotoxic oedema, i.e., to the change in relative volume of intra‐ and extracellular spaces. Changes in membrane permeability do not appear to contribute significantly to the changes in diffusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system.
Moseley, M. E., Cohen, Y., Kucharczyk, J., Mintorovitch, J., Asgari, H. S., Wendland, M. F., Tsuruda, J., & Norman, D. (1990) · Radiology · doi:10.1148/radiology.176.2.2367658 · Cited by 1,133
Stejskal, E. O. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1696526 · Cited by 894
(2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.45-12.s8 · Cited by 890
Fast magnetic resonance diffusion-weighted imaging of acute human stroke
Warach, S., Chien, D., Li, W., Ronthal, M., & Edelman, R. R. (1992) · Neurology · doi:10.1212/wnl.42.9.1717 · Cited by 881
Benveniste, H., Hedlund, L. W., & Johnson, G. A. (1992) · Stroke · doi:10.1161/01.str.23.5.746 · Cited by 508
Mintorovitch, J., Moseley, M. E., Chileuitt, L., Shimizu, H., Cohen, Y., & Weinstein, P. R. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180106 · Cited by 507
The spatial mapping of translational diffusion coefficients by the NMR imaging technique
Taylor, D. G., & Bushell, M. C. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/009 · Cited by 344
Minematsu, K., Li, L., Sotak, C. H., Davis, M. A., & Fisher, M. (1992) · Stroke · doi:10.1161/01.str.23.9.1304 · Cited by 320
Busza, A. L., Allen, K. L., King, M. D., van Bruggen, N., Williams, S. R., & Gadian, D. G. (1992) · Stroke · doi:10.1161/01.str.23.11.1602 · Cited by 311
Self-diffusion NMR imaging using stimulated echoes
Merboldt, K.-D., Hanicke, W., & Frahm, J. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90111-8 · Cited by 307
Minematsu, K., Li, L., Fisher, M., Sotak, C. H., Davis, M. A., & Fiandaca, M. S. (1992) · Neurology · doi:10.1212/wnl.42.1.235 · Cited by 297
Tanner, J. E. (1978) · The Journal of Chemical Physics · doi:10.1063/1.436751 · Cited by 296
MR diffusion imaging of cerebral infarction in humans.
(1992) · PubMed Central · Cited by 258
Van Zijl, P. C., Moonen, C. T., Faustino, P., Pekar, J., Kaplan, O., & Cohen, J. S. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.8.3228 · Cited by 220
Self-citationKnight, R. A., Ordidge, R. J., Helpern, J. A., Chopp, M., Rodolosi, L. C., & Peck, D. (1991) · Stroke · doi:10.1161/01.str.22.6.802 · Cited by 206
Dardzinski, B. J., Sotak, C. H., Fisher, M., Hasegawa, Y., Li, L., & Minematsu, K. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300307 · Cited by 170
Davis, D., Ulatowski, J., Eleff, S., Izuta, M., Mori, S., Shungu, D., & van Zijl, P. C. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310416 · Cited by 166
Self-citationOn the precision of diffusion/perfusion imaging by gradient sensitization
Pekar, J. J., MOONEN, C. T. W., & van Zijl, P. C. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230113 · Cited by 153
Self-citationWater diffusion permeability of human erythrocytes studied by a pulsed gradient NMR technique
Andrasko, J. (1976) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(76)90038-6 · Cited by 145
MOONEN, C. T. W., Pekar, J. J., de Vleeschouwer, M. H. M., van Gelderen, P., van Zijl, P. C. M., & Despres, D. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190223 · Cited by 129
Self-citationMeasuring Random Microscopic Motion of Water in Tissues with MR Imaging: A Cat Brain Study
Bihan, D. L., MOONEN, C. T. W., van Zijl, P. C. M., Pekar, J. J., & Despres, D. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199101000-00002 · Cited by 106
Self-citationA review of water diffusion measurement by NMR in human red blood cells
Herbst, M. D., & Goldstein, J. H. (1989) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1989.256.5.c1097 · Cited by 104
ALLEGRINI, P. R., & Sauer, D. (1992) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(92)90411-r · Cited by 85
Interpreting pulsed-gradient spin–echo diffusion experiments with permeable membranes
Meerwall, E. V., & Ferguson, R. D. (1981) · The Journal of Chemical Physics · doi:10.1063/1.441059 · Cited by 84
Extracellular space of the cerebral cortex of normothermic and hypothermic cats
Fenstermacher, J. D., Li, C., & Levin, V. A. (1970) · Experimental Neurology · doi:10.1016/0014-4886(70)90205-0 · Cited by 71
Molecular mechanisms of glial swelling in vitro
Kempski, O. S., Staub, F., Rosen, F., Zimmer, M., Neu, A. D., & Baethmann, A. J. (1988) · Neurochemical Pathology · doi:10.1007/bf03160357 · Cited by 58
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Fiber tracking: principles and strategies – a technical review
Mori, S., & van Zijl, P. C. M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.781 · Cited by 2,024
Self-citation
Metadata
- Authors
- van Gelderen, P., de Vleeschouwer, M. H. M., DesPres, D., Pekar, J., van Zijl, P. C. M., & Moonen, C. T. W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-02
- Volume
- 31
- Issue
- 2
- Pages
- 154-163
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1980357202
- Cited by
- 410
- References
- 28
- FWCI
- 20.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.