Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 252

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Reduction of signal fluctuation in functional MRI using navigator echoes

Hu, Xiaoping, Kim, Seong‐Gi · 1994 · Magnetic Resonance in Medicine

Abstract

Functional magnetic resonance imaging is sensitive to signal fluctuations due to physiological motion and system instability. In this paper, motion‐related signal fluctuations are studied, and a method that uses navigator echoes to monitor and compensate for signal fluctuations in a gradient‐echo sequence is described. The technique acquires a “navigator” signal before the application of the phase‐encoding and readout gradients and corrects the phase of the subsequently acquired imaging data. This technique was implemented on a 4 Tesla whole body system and validated on normal volunteers. With this technique, temporal fluctuations in image intensity were substantially reduced and improved functional activation maps were obtained.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910310505

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 252

Metadata

Authors
Hu, X., & Kim, S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1994-05
Volume
31
Issue
5
Pages
495-503
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2133631302
Cited by
252
References
23
FWCI
14.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduction of signal fluctuation in functional MRI using navigator echoes. https://app.cochat.ai/papers/10.1002/mrm.1910310505
The paper
Hu, X., & Kim, S. (1994). Reduction of signal fluctuation in functional MRI using navigator echoes. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910310505

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.