Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Motion Artifacts in fMRI: Comparison of 2DFT with PR and Spiral Scan Methods

Glover, Gary H., Lee, Adrian T.·1995·Magnetic Resonance in Medicine

Abstract

Activation signals based on BOLD contrast changes consequent to neuronal stimulation typically produce cortical intensity differences of < 10% at 1.5T. Hemodynamically driven pulsation of the brain can cause highly pulsatile phase shifts, which in turn result in motion artifacts whose intensity is larger than the activation signals in 2DFT scan methods. This paper presents a theoretical and experimental comparison of the magnitude of such artifacts for 2DFT and two other methods using non‐Cartesian k‐space trajectories. It is shown that artifacts increase with TR for 2DFT methods, and that projection reconstruction (PR) and spiral methods have significantly reduced artifact intensities, because these trajectories collect low spatial frequencies with every view. The spiral technique is found to be superior in terms of efficiency and motion insensitivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910330507

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 200

Metadata

Authors
Glover, G. H., & Lee, A. T.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1995-05
Volume
33
Issue
5
Pages
624-635
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2040486018
Cited by
200
References
4
FWCI
16.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Motion Artifacts in fMRI: Comparison of 2DFT with PR and Spiral Scan Methods. https://app.cochat.ai/papers/10.1002/mrm.1910330507
The paper
Glover, G. H., & Lee, A. T. (1995). Motion Artifacts in fMRI: Comparison of 2DFT with PR and Spiral Scan Methods. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910330507

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.