The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Correction for geometric distortion in echo planar images from B 0 field variations
Abstract
A method is described for the correction of geometric distortions occurring in echo planar images. The geometric distortions are caused in large part by static magnetic field inho‐mogeneities, leading to pixel shifts, particularly in the phase encode direction. By characterizing the field inhomogeneities from a field map, the image can be unwarped so that accurate alignment to conventionally collected images can be made. The algorithm to perform the unwarping is described, and results from echo planar images collected at 1.5 and 4 Tesla are shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Image Analysis Using Mathematical Morphology
Haralick, R. M., Sternberg, S. R., & Zhuang, X. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767941 · Cited by 2,710
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H., Kwong, K. K., Le Bihan, D., Zeffiro, T., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 457
Self-citationTwieg, D. B. (1983) · Medical Physics · doi:10.1118/1.595331 · Cited by 373
Farzaneh, F., Riederer, S. J., & Pelc, N. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140112 · Cited by 362
A simple graphical representation of fourier-based imaging methods
Ljunggren, S. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90060-4 · Cited by 292
Schneider, E., & Glover, G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180208 · Cited by 221
Biological and medical imaging by NMR
Mansfield, P., & Pykett, I. L. (1978) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(78)90159-2 · Cited by 186
Instant images of the human heart using a new, whole-body MR imaging system
Rzedzian, R. R., & Pykett, I. L. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.149.2.245 · Cited by 139
Cited by
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Jenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W., & Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.015 · Cited by 11,314
The minimal preprocessing pipelines for the Human Connectome Project
Glasser, M. F., Sotiropoulos, S. N., Wilson, J. A., Coalson, T. S., Fischl, B., Andersson, J. L., Xu, J., Jbabdi, S., Webster, M., Polimeni, J. R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.127 · Cited by 5,253
Accurate and robust brain image alignment using boundary-based registration
Greve, D. N., & Fischl, B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.060 · Cited by 3,596
Andersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469
Metadata
- Authors
- Jezzard, P., & Balaban, R. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-07
- Volume
- 34
- Issue
- 1
- Pages
- 65-73
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2071472234
- Cited by
- 1,421
- References
- 12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.