The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
The rician distribution of noisy mri data
Open accessAbstract
The image intensity in magnetic resonance magnitude images in the presence of noise is shown to be governed by a Rician distribution. Low signal intensities (SNR < 2) are therefore biased due to the noise. it is shown how the underlying noise can be estimated from the images and a simple correction scheme is provided to reduce the bias. the noise characteristics in phase images are also studied and shown to be very different from those of the magnitude images. Common to both, however, is that the noise distributions are nearly Gaussian for SNR larger than two.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probability, Random Variables, and Stochastic Processes.
Abrahams, J., & Papoulis, A. (1984) · Journal of the American Statistical Association · doi:10.2307/2288754 · Cited by 16,226
Mathematical Analysis of Random Noise
Rice, S. O. (1944) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1944.tb00874.x · Cited by 5,480
Measurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
Modern Digital and Analog Communications Systems
Lathi, B. P. (1983) · CERN Document Server (European Organization for Nuclear Research) · Cited by 776
The sensitivity of the zeugmatographic experiment involving human samples
Hoult, D. I., & Lauterbur, P. C. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90019-2 · Cited by 776
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Automatic detection of brain contours in MRI data sets
Brummer, M. E., Mersereau, R. M., Eisner, R. L., & Lewine, R. R. J. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232244 · Cited by 297
The use of power images to perform quantitative analysis on low SNR MR images
Miller, A. J., & Joseph, P. M. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90225-3 · Cited by 244
Edelstein, W. A., Bottomley, P. A., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595484 · Cited by 230
An unbiased signal‐to‐noise ratio measure for magnetic resonance images
McGibney, G., & Smith, M. R. (1993) · Medical Physics · doi:10.1118/1.597004 · Cited by 194
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Denoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Metadata
- Authors
- Gudbjartsson, H., & Patz, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-12
- Volume
- 34
- Issue
- 6
- Pages
- 910-914
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2059784307
- Cited by
- 2,494
- References
- 10
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.